background image

c.  Validate the voltage outputs of  the Kronus 1 are active by adjusting the dials to the lowest 

setting and using a voltage test meter, fan or 120 Volt light to verify power is flowing through the 
controller.

d. Ensure that your equipment is ‘ON’ and set at the maximum level.

e.  Verify that the Kronus 1 is set at the proper levels to activate and deactivate equipment. 

f.  If your equipment does not turn off, verify that your exhaust fan or dehumidifier are the correct 

size for your grow area.  Increase size of equipment, (if necessary).

g.  Check the remote sensor to verify that the green LED is steady ‘ON’ and NOT blinking.

h.  If the green ‘ON’ LED on the Kronus Temperature and Humidity sensor is blinking, there is a 

communication problem between the sensor and the controller. Contact your Dealer or our 
Technical Service Representative to assist you. 

i.  If you are still having problems with your Kronus 1, please contact our Technical Service 

Representative to assist you further.

Controller Specifications:

• Size = 9.5”H x 8.5”W x 2.5”D

• Weight = 3 lbs.

• Input Voltage = 120 Volts/AC 

• Output Voltage = 120 Volts/AC 

• Maximum Amperage = 15 Amps

• Operating Hertz = 60 Hz

• Minimum/Maximum Humidity Control Levels = 40% to 90% (non-condensing)

• Humidity Accuracy = ±5% of desired setting

• Minimum/Maximum Temperature Control Levels = 45° to 95°F (7° to 35°C)

• Temperature Accuracy = ± 2°F of desired setting

• RoHS compliant = Yes

• Cord set = 6 feet - 14/4 SWJ

• Remote Sensor Cable = 25 feet/Cat 5e/RJ45

• Storage Temperature = 32° to 135°F (0° to 58°C)

• Operating Temperature = 45° to 95°F (7° to 35°C)

Installation Example

Kr

onus 1

120 V

olt

Power in

Dehumidifier

Exhaust Fan

Remote  Sensor (25 feet)

Kr

onus 

Sensor

Controlling a Dehumidifier & Exhaust Fan

Summary of Contents for Kronus 1

Page 1: ...tes _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ _________________________________________________ ________________________________________________ 1 Square 1 Foot ...

Page 2: ...turn it to us for factory repair If there are no Dealers in your area you may contact us directly for technical support If we cannot help you resolve the problem over the phone we will issue you a RMA number Return Merchandise Authorization authorizing you to return the unit to us for factory reconditioning if the unit is under warranty Contact the number below for a RMA and shipping address Compl...

Page 3: ...in material and workmanship under normal use for three 3 years from the date of purchase During the warranty period Titan Controls will at our option and without charge repair or replace this product if the controller or any of its components fail or malfunction All returns or repairs must be accompanied by a Return Merchandise Authorization RMA number prior to any service of the product This warr...

Page 4: ...en the sensor and the controller Contact your Dealer or our Technical Service Representative to assist you i If you are still having problems with your Kronus 1 please contact our Technical Service Representative to assist you further Controller Specifications Size 9 5 H x 8 5 W x 2 5 D Weight 3 lbs Input Voltage 120 Volts AC Output Voltage 120 Volts AC Maximum Amperage 15 Amps Operating Hertz 60 ...

Reviews: