GAS ENGINE (WHERE APPLICABLE)

Always place sprayer outside of structure in fresh air.  Keep all
solvents away from engine exhaust.  Never fill fuel tank with a
running or hot engine.  Hot surface can ignite spilled fuel.
Always attach ground wire from pump to a grounded object.
Refer to engine owner’s manual for complete safety
information.

HAZARD: EXPLOSION HAZARD DUE TO INCOMPATIBLE

MATERIALS - will cause severe injury or
property damage.

PREVENTION:

• Do not use materials containing bleach or chlorine.
• Do not use halogenated hydrocarbon solvents such as

bleach, mildewcide, methylene chloride and 1,1,1 -
trichloroethane.  They are not compatible with aluminum.

•  Contact your coating supplier about the compatibility of

material with aluminum.  

HAZARD: HAZARDOUS VAPORS -  Paints, solvents,

insecticides, and other materials can be
harmful if inhaled or come in contact with body.
Vapors can cause severe nausea, fainting, or
poisoning.

PREVENTION:

• Use a respirator or mask if vapors can be inhaled.  Read

all instructions supplied with the mask to be sure it will
provide the necessary protection. 

• Wear protective eyewear.
• Wear protective clothing as required by coating

manufacturer.

HAZARD:  GENERAL - Can cause severe injury or

property damage.

PREVENTION:

• Read all instructions and safety precautions before

operating equipment.

• Follow all appropriate local, state, and national codes

governing ventilation, fire prevention, and operation. 

• The United States Government Safety Standards have

been adopted under the Occupational Safety and Health
Act (OSHA).  These standards, particularly part 1910 of
the General Standards and part 1926 of the Construction
Standards, should be consulted.

• Use only manufacturer authorized parts.  User assumes

all risks and liabilities when using parts that do not meet
the minimum specifications and safety devices of the
pump manufacturer.

• Before each use, check all  hoses for cuts, leaks, abrasion

or bulging of cover.  Check for damage or movement of
couplings.  Immediately replace hose if any of those
conditions exist.  Never repair a paint hose.  Replace with
a grounded high-pressure hose.

• All hoses, swivels, guns, and accessories must be

pressure rated at or above 3300PSI/228 BAR.

• Do not spray outdoors on windy days.
• Wear clothing to keep paint off skin and hair.
• Always unplug cord from outlet before working on

equipment.

Grounding Instructions

This product must be grounded. In the event of an electrical
short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This product
is equipped with a cord having a grounding wire with an
appropriate grounding plug. The plug must be plugged into an
outlet that is properly installed and grounded in accordance
with all local codes and ordinances.

DANGER

— Improper installation of the grounding plug can

result in a risk of electric shock.  If repair or replacement of the
cord or plug is necessary, do not connect the green grounding
wire to either flat blade terminal. The wire with insulation
having a green outer surface with or without yellow stripes is
the grounding wire and must be connected to the grounding
pin.

Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if you
are in doubt as to whether the product is properly grounded.
Do not modify the plug provided.  If the plug will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
This product is for use on a nominal 120 volt circuit and has a
grounding plug that looks like the plug illustrated below. A
temporary adapter which looks like the adapter illustrated in
the figure below may be used to connect this plug to a 2 pole
receptacle as shown if a properly grounded outlet is not
available. 
The temporary adapter should be used only until a properly
grounded outlet as shown below can be installed by a qualified
electrician. The green colored rigid ear, lug, or the grounding
wire extending from the adapter must be connected to a
permanent ground such as a properly grounded outlet box
cover. Whenever the adapter is used, it must be held in place
by a metal screw.

Use only a 3-wire extension cord that has a 3-blade
grounding plug and a 3-slot receptacle that will accept the
plug on the product.  Make sure your extension cord is in
good condition.  When using an extension cord, be sure
to use one heavy enough to carry the current your
product will draw.  An undersized cord will cause a drop
in line voltage resulting in loss of power and overheating.
A 12 gauge cord is recommended.  If an extension cord is
to be used outdoors, it must be marked with the suffix W-
A after the cord type designation.  For example, a
designation of SJTW-A would indicate that the cord would
be appropriate for outdoor use.

CAUTION

Grounded Outlet

Grounding Pin 

Tab for
Grounding Screw 

Adapter

Metal Screw

Cover for grounded outlet box 

© Titan Tool Inc.  All rights reserved.

3

Summary of Contents for 1140ix

Page 1: ...yer Owner s Manual For professional use only NOTE This manual contains important warnings and instructions Please read and retain for reference NOTE This manual contains important warnings and instruc...

Page 2: ...Refer to the PRESSURE RELIEF PRESSURE described in the pump manual ALWAYS keep tip guard in place while spraying The tip guard provides some protection but is mainly a warning device ALWAYS remove th...

Page 3: ...uct must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This product is equipped with a cord...

Page 4: ...ned out of the system with mineral spirits before you begin spraying Always keep the trigger lock on the spray gun in the locked position while preparing the system 1 Place the siphon tube into a cont...

Page 5: ...he gun into the metal waste container until all air and solvent is flushed from the spray hose and paint is flowing freely from the gun WARNING On Off Clean Min PSI Bar Max PSI Bar S p r a y L a t e x...

Page 6: ...up of static electricity 5 Trigger the gun to remove any pressure that may still be in the hose 6 Lock the gun by turning the gun trigger lock to the locked position 7 Move the PRIME SPRAY valve down...

Page 7: ...olvent WARNING CAUTION WARNING Good spray pattern Paint tailing pattern Titan Tool Inc All rights reserved 7 3 Place the siphon tube into a container of the appropriate solvent Examples of the appropr...

Page 8: ...stem with the hole in the valve handle 7 Insert the groove pin into the valve handle and through the valve stem to secure the valve handle in position Gasket Dowel Pin Cam Base Valve Stem Filter Housi...

Page 9: ...the four motor shroud screws Remove the motor shroud 3 Release the tie wrap on the top of the baffle assembly and slip the baffle assembly down off of the motor 4 Loosen and remove the three electroni...

Page 10: ...rn off and unplug the unit Before proceeding follow the Pressure Relief Procedure outlined previously in this manual Additionally follow all other warnings to reduce the risk of an injection injury in...

Page 11: ...ng kit over the top of the piston rod 20 Insert the piston rod into the bottom of the upper housing through the lower packing through the upper packing and out through the upper seal retainer 21 Remov...

Page 12: ...er tripped 1 Air in line 2 Insufficient pressure 1 No paint 2 Siphon strainer clogged 3 Sprayer gun filter clogged 4 Sprayer will not prime material too heavy 1 Air leak in system 2 Air leak in siphon...

Page 13: ...ayer capacity 1 Worn tip 2 Tip may be chipped 1 Plugged worn or chipped tip 1 Leak in suction tube 2 Not enough hose 3 Tip too large or worn Solution 1 Increase pressure 2 Change to smaller tip 3 Clea...

Page 14: ...ntion particuli re ATTENTION AVERTISSEMENT DANGER RISQUES D EXPLOSION OU D INCENDIE Les vapeurs d gag es par le solvant ou la peinture sont explosives et inflammables et peuvent causer des corporels s...

Page 15: ...t Ne jamais r parer un flexible d alimentation en peinture Le remplacer par un autre flexible mis la terre Tout flexible raccord orientable pistolet et accessoire utilis avec cet appareil doit pouvoir...

Page 16: ...PARA PREVENIR Debe proveerse un escape y aire fresco para hacer que el aire que est dentro del rea de atomizaci n se mantenga libre de acumulaciones de vapores inflamables Evite todas las fuentes de i...

Page 17: ...ierra reduce el riesgo de choque el ctrico al proporcionar un alambre de escape para la corriente el ctrica Este producto est equipado con un cable que tiene un alambre de conexi n a tierra con un enc...

Page 18: ...551 Lock washer 2 7 858 625 Screw 2 8 800 328 Knock off nut 1 9 800 300 Fluid section assembly 1 10 451 241 Siphon tube 1 11 730 334 Hose clamp 1 Item Part Description Quantity 12 710 046 Inlet screen...

Page 19: ...753 Connecting pin 1 17 800 202 Screw 2 18 800 276 Relay 1 19 704 229 Screw 1 20 765 327 Circuit breaker 1 21 800 075 Mounting plate 1 Item Part Description Quantity 22 800 077 Grommet 1 23 800 076 S...

Page 20: ...packing with the side that has the o ring closest to the top of the packing facing up Install upper packing with raised lip facing down Raised Lip 22 Closer Top NOTE When repacking the fluid section...

Page 21: ...des items 10 16 1 800 359 Lower packing insertion tool 800 273 Repacking kit includes items 2 3 5 8 11 13 14 18 20 and tool High Rider Cart P N 800 600 Item Part Description Quantity 1 800 280 Handle...

Page 22: ...ess to Reset label 313 1848 Pressure control knob label 313 1867 Indicator lights label 313 1652 Titan front label 313 1906 Infinity logo label Low Rider Cart P N 800 590 1 2 3 4 5 6 7 8 9 10 11 12 13...

Page 23: ...likely to plug Liquid Shield Plus Cleans and protects spray systems against rust corrosion and premature wear Part No Description 314 483 4 ounce bottle 314 482 1 quart bottle Piston Lube Specially fo...

Page 24: ...on substitution of non Titan component parts or tampering with the unit in a manner to impair normal operation Defective parts are to be returned to an authorized Titan sales service outlet All transp...