English
English
4
© Titan Tool Inc. All rights reserved.
General Description
This airless sprayer is a precision power tool used for spraying
many types of materials. Read and follow this instruction manual
carefully for proper operating instructions, maintenance, and safety
information.
11*
PRIME
SPRAY
k
p
5
7
8
9
11*
12
10
4
3
6
1
13
14
2
Item
Description
1
Motor
2
Pressure control knob
3
ON/OFF switch
4
Oiler cap
5
Oiler button
6
Pail bracket
7
Fluid section
8
Siphon tube
9
Return hose
10
Filter
11
PRIME/SPRAY valve
12
Outlet fitting
13
Liquid Shield™ (4 oz.)
14
Piston Lube™ (4 oz.)
Operation
This equipment produces a fluid stream at extremely
high pressure. read and understand the warnings
in the Safety Precautions section at the front of this
manual before operating this equipment.
Locking the Spray Gun
1. To lock the trigger, rotate the trigger lock forward until it
stops.
2. To unlock the trigger, rotate the trigger lock backwards until it
is vertical.
Trigger locked (gun
will not spray)
Trigger unlocked
(gun will spray)
Pressure relief Procedure
Be sure to follow the Pressure relief Procedure when
shutting down the sprayer for any purpose, including
servicing or adjusting any part of the spray system,
changing or cleaning spray tips, or preparing for
cleanup.
1. Lock the gun by turning the gun trigger lock to the locked
position.
2. Move the PRIME/SPRAY valve down to the PRIME position.
3. Turn off the sprayer by moving the ON/OFF switch to the OFF
position.
4. Turn the pressure control knob counterclockwise to its OFF
position in the black zone.
5. Unlock the gun by turning the gun trigger lock to the
unlocked position.
6. Hold the metal part of the gun firmly to the side of a metal
container to ground the gun and avoid a build up of static
electricity.
7. Trigger the gun to remove any pressure that may still be in the
hose.
8. Lock the gun by turning the gun trigger lock to the locked
position.