Performance Series 560e
9
GB
Handling the high-pressure hose
Cleaning the unit (shutting down)
6.
Handling the high-pressure hose
The unit is equipped with a high-pressure hose specially suited for
piston pumps.
Danger of injury through leaking high-pressure
hose. Replace any damaged high-pressure hose
immediately.
Never repair defective high-pressure hoses yourself!
The high-pressure hose is to be handled with care. Avoid sharp
bends and folds: the smallest bending radius is about 20 cm.
Do not drive over the high-pressure hose. Protect against sharp
objects and edges.
Never pull on the high-pressure hose to move the device.
Make sure that the high-pressure hose cannot twist. This can be
avoided by using a Titan spray gun with a swivel joint and a hose
system.
i
When using the high-pressure hose while working
on scaffolding, it is best to always guide the hose
along the outside of the scaffolding.
i
The risk of damage rises with the age of the high-
pressure hose. Titan recommends replacing high-
pressure hoses after 6 years.
i
Use only Titan original-high-pressure hoses in order
to ensure functionality, safety and durability.
7.
Interruption of work
1. Open the relief valve, valve position PRIME (
k
circulation).
2. Switch the unit OFF.
3. Turn the pressure control knob counterclockwise to minimum
pressure.
4. Pull the trigger of the spray gun in order to release the
pressure from the high-pressure hose and spray gun.
5. Secure the spray gun, refer to the operating manual of the
spray gun.
6. If a standard tip is to be cleaned, see Page 16, Section 12.2.
If a non-standard tip is installed, proceed according to the
relevant operating manual.
7. Depending on the model, leave the suction tube or the
suction hose and return hose immersed in the coating
material or swivel or immerse it into a corresponding cleaning
agent.
Attention
If fast-drying or two-component coating material is
used, ensure that the unit is rinsed with a suitable
cleaning agent within the processing time.
8.
Cleaning the unit (shutting down)
A clean state is the best method of ensuring operation without
problems. After you have finished spraying, clean the unit. Under no
circumstances may any remaining coating material dry and harden in
the unit.
The cleaning agent used for cleaning (only with an igni tion point
above 38 °C) must be suitable for the coating material used.
• Secure the spray gun, refer to the operating manual of the
spray gun.
Clean and remove tip.
For a standard tip, refer to Page 16, Section 12.2.
If a non-standard tip is installed, proceed according to the relevant
operating manual.
1. Remove suction hose from the coating material.
2. Close the relief valve, valve position SPRAY (
p
spray).
3. Switch the unit ON.
4. Pull the trigger of the spray gun in order to pump the
remaining coating material from the suction hose, high-
pressure hose and the spray gun into an open container.
Attention
The container must be earthed in case of coating
materials which contain solvents.
Caution! Do not pump or spray into a container with
a small opening (bunghole)!
Refer to the safety regulations.
5. Immerse suction hose with return hose into a container with a
suitable cleaning agent.
6. Turn the pressure control knob into the blue zone - pulsating
pressure for unit cleaning.
7. Open the relief valve, valve position PRIME (
k
circulation).
8. Pump a suitable cleaning agent in the circuit for a few
minutes.
9. Close the relief valve, valve position SPRAY (
p
spray).
10. Pull the trigger of the spray gun.
11. Pump the remaining cleaning agent into an open container
until the unit is empty.
12. Switch the unit OFF.
8.1
Cleaning unit from outside
First of all pull out mains plug from socket.
Attention
Danger of short circult through panetrating water!
Never spray down the unit with high-pressure or
high-pressure steam cleaners.
Attention
Do not put the high-pressure hose into solvents.
Use only a wet cloth to wipe down the outside of the
hose.
Wipe down unit externally with a cloth which has been immersed in a
suitable cleaning agent.