CHAPTER 5 : MAINTENANCE SCHEDULE
MAINTENANCE SCHEDULE : to prolong the life time of your TITAN Machine.
TO DO EVERY 8 HOURS (+/- DAY)
•
Blow clear the machine with compressed air at the end of each shift!
TO DO EVERY 40 HOURS (WEEK)
•
Change needle every 40 working hours .
•
Before replacement of the needle, thoroughly remove any dust that may have
accumulated round the needle holder.
•
Remove dust beneath both the stitch plate and the feed-dog
once a week!
•
Check oil level every week + add oil accordingly.
TO DO EVERY 200 HOURS (MONTH)
•
Change the oil once a month minimum! OIL TYPE : 15W30
•
Check and if necessary replace any worn out parts such as
loopers, knives, needle guide, chain guide with new ones.!
TO DO EVERY YEAR
•
Check if the parts are still mounted tightly, if there is no play on the upper and
lower looper – needle bar – knifes and other parts. Open up the machine and
replace necessary parts such as bearings, and others
•
If you have no maintenance engineer, you can send back your sewing head,
and the company DE KONINCK will give service to you. Consult our technical
or sales department at TEL +32-2-216.31.40 or by email at :
info@titansew.com
From the Library of Superior Sewing Machine & Supply LLC