11
DESCRIPTION OF UNIT
HYDRA X
3.5
TECHNICAL DATA
4500 PSI
7250 PSI
Gasoline engine, power
Honda
389cc, 11.7 Hp,
8.7 kW
389cc, 11.7 Hp,
8.7 kW
Fuel Capacity
1.6 US gal (6.06 l)
1.6 US gal (6.06 l)
Max. operating pressure
4500 PSI
7250 PSI
Max. sound pressure level
98 dB (A)*
98 dB (A)*
Max. size of tip with a spray gun
1-gun
0.067” – 1.70 mm
0.065” – 1.65 mm
2-gun
0.041” – 1.04 mm
0.035” – 0.89 mm
3-gun
0.035” – 0.89 mm
0.028” – 0.71 mm
4-gun
0.031” – 0.79 mm
0.025” – 0.63 mm
5 gun
0.029” – 0.73 mm
0.021” – 0.53 mm
6 gun
0.025” – 0.63 mm
Max. volume flow
4.0 gal (15.1 l)/min 2.8 gal (10.6 l)/min
Weight
390 lbs (177 kg)
390 lbs (177 kg)
Suction system
Siphon tube
Siphon tube
Max. viscosity
65,000 mPa·s
65,000 mPa·s
Dimensions L x W x H
48” x 32” x 52”
48” x 32” x 52”
Max. temperature of the coating material
109ºF (43° C)
109ºF (43° C)
Hydraulic oil filling quantity
22.7 l (6.0 gal)
22.7 l (6.0 gal)
Max. tire pressure
0.2 MPa (2 bar, 30
PSI)
0.2 MPa (2 bar, 30
PSI)
* Place of measurement: 1 m distance from unit and 1.60
m above reverberant floor, 120 bar (12 MPa) operating
pressure.
OPERATING TEMPERATURE
This equipment will operate correctly in its intended ambient,
at a minimum b50ºF (10°C) and 104ºF (+40°C).
RELATIVE HUMIDITY
The equipment will operate correctly within an environment
at 50% RH, 104ºF (+40°C). Higher RH may be allowed at lower
temperatures.
Measures shall be taken by the Purchaser to avoid the harmful
effects of occasional condensation.
ALTITUDE
This equipment will operate correctly up to 2100 m above
mean sea level.
Contact your local Honda representative for operating the unit
above 2100m above mean sea level.
TRANSPORTATION AND STORAGE
This equipment will withstand, or has been protected against,
transportation and storage temperatures of -13ºF (-25°C) to
131ºF (+55°C) and for short periods up to 150ºF (+70°C).
Fluid pump should be stored in glycol below 32ºF (0ºC).
It has been packaged to prevent damage from the effects of
normal humidity, vibration and shock.