8
Performance Series 750e
GB
Description of unit
Starting operation
3.5
Technical data
Voltage:
110 Volt AC, 50/60 Hz
Max. current consumption:
12.5 A @ 110VAC
Power cord:
3 x 1.5 mm
2
– 6 m
Acceptance capacity:
950 Watt
Max. operating pressure:
214 bar (21,4 MPa)
Volume flow at 12 MPa
(120 bar) with water:
2.46 l/min
Max tip size:
0.027 inch – 0.68 mm
Max. temperature of the
coating material:
43°C
Max viscosity:
25.000 mPa·s
Weight:
Stand:
21.2 kg
Cart:
29.5 kg
Special high-pressure hose:
6,35 mm, 15 m-18 NPSM
Dimensions (L X W X H):
Stand:
480 x 360 x 405 mm
Cart:
615 x 530 x 730 mm
Max sound pressure level:
80 dB (A) *
* Place of measuring: 1 m in distance from the unit and 1.6
m above the floor, 12 MPa (120 bar) operating pressure,
reverberant floor.
3.6
Transportation
Pushing or pulling the unit
Pull out the handle (Fig. 2, Item 1) until it will come no further.
Insert the handle – push the buttons (2) on the spars, and then
push in the handle.
2
2
1
3.7 Transportation in vehicle
Secure the unit with a suitable fastening.
4.
Starting operation
4.1
High-pressure hose, spray gun and
separating oil
1. Screw the pressure gauge (1) to the coating material
outlet (Fig. 3, Item 2).
2. Screw the high-pressure hose (3) to the coating material
outlet on the pressure gauge (Fig. 3, Item 4).
3. Screw the spray gun (5) with the selected tip onto the
high-pressure hose.
4. Tighten the union nuts at the high-pressure hoses firmly
so that coating material does not leak.
5
1
4
2
3
5. Fill the oil cup with Piston Lube (Fig. 4). Do not use too
much Piston Lube, i.e. ensure that no Piston Lube drips
into the coating material container.
Attention
Piston Lube prevents increased wear and tear to
the packings.