19
SHUTTING DOWN AND CLEANING
PowrMax
POWER
ERROR
SPEED
R
A
F
2
1
4
3
3
6
5
7
CLEAN THE OUTLET UNIT
1. Clean the outlet unit (4) with a jet of water and a suitable
bottle brush.
2. Clean the container (7) with a jet of water and a suitable
brush.
3. Clean the protective grid with a radiator brush.
4. Also clean the rotor (6) and stator (5) thoroughly with
water and, if necessary, using a brush.
5. Then spray rotor (6) and stator (5) and with a suitable
pump lubricant.
6. Keep the thread of the pump housing and the pump tube
clean so that leaking after the assembly is avoided.
MOUNTING
i
If the machine is down for a longer period of
time, the stator can become set at the rotor.
Therefore, if the stator has been in storage for a
longer period of time, do not mount it until you
are about to begin work.
Assembly, see chapter 6.2.2
8.3
CLEANING THE SPRAY LANCE
1. Clean the texture tip.
2. Use cleaning needles to clean the air holes in the texture
tip.
3. Clean and lubricate the O-ring (fig. 15, 1).
4. Clean the spray lance and material tube on the inside using
a bottle brush (0342 329).
5. Clean all threads thoroughly.
6. Rinse the spray lance with clear water. Open and close the
material tap three times as you are doing this.
1