20
MAINTENANCE
PowrMax
9
MAINTENANCE
ATTENTION! It is imperative that the machine be
deenergized by unplugging the plug before all
work and maintenance work. Otherwise there is
a danger of short-circuiting!
Repairs may only be carried out by qualified
personnel who dispose the corresponding
training and experience. The device must be
tested by a skilled electrician after every repair.
The mortar spraying machine is designed so that a minimum of
care and maintenance is required. However, the following work
has to be carried out and components checked regularly:
9.1
MECHANICAL MAINTENANCE
•
Keep the thread at the pump tube and pump housing
clean and, if appropriate, seal.
•
Check the seals at all the couplings and connecting pieces
for leaks. If appropriate, replace worn seals.
•
Check the following for damage before every usage:
- Mortar hose
- Power cable
- Control unit
9.2
ELECTRICAL MAINTENANCE
•
The electrical drive and its ventilation slots must always be
kept clean and may not be cleaned with water. Danger of
short-circuits.
9.3
LONG PERIODS OF NON-USAGE
If the mortar spraying machine is not used for a longer period, it
has to be cleaned thoroughly and protected against corrosion.
i
Take the stator out of the pump unit so that it
cannot get stuck to the rotor.
9.4
SHAFT SEAL (FIG. 16)
i
Check the seals on the PowrMax 605 every
month.
1. Move selector switch (fig. 16, 1) to “A” and set delivery
volume controller (2) to „0“.
2. Disconnect mains plug.
3. Loosen the star screws (3) and remove the outlet unit (4).
4. Set delivery volume controller (2) to 1 or 2.
5. Connect mains plug to mains power supply.
6. Move the selector switch (1) to position „F“. As soon as
the stator (5) is released from the rotor (6), set the selector
switch to „A“.
7. Remove the stator (5) completely.
8. Disconnect mains plug.
9. Pull out the two locking pins (7) and remove the anti-twist
lock (8).
10. Remove the flange (9) with a 17-wrench.
11. Remove the container (10).
12. Check the seal (11) and replace if necessary.
13. Clean the shaft seal (12).
14. Check the rotor (6) and replace if necessary (see chapter
9.5).