35
PowrPlast 600
GB
4.1
OPeRAtING eLeMeNtS AND DISPLAyS ON
DeVIce
1
Delivery volume controller
0-10
2 Selector switch for operating mode
3 Indicator light (Error)
4 Operating light (Power)
5 EMERGENCY STOP switch
The delivery volume controller (
Fig. 3, 1) is used to regulate
the convey capacity from 0-10 smoothly.
The remote control (available separately, art.
no. 2308 417) can be used to conveniently
control the pump‘s delivery volume from the
spray lance.
The selector switch (Fig. 3, 2) offers the following modes:
A
R
F
“A” position = automatic
Basic setting for control with an automatic
spray lance, pneumatic spray lance or re
-
mote control
A
R
F
“F” position = manual activation
Switches on the mortar spraying machine.
This setting is required for:
• suction unit assembly
When using the pneumatic lance, this set-
ting is also needed for:
• pre-rinsing the mortar hose to improve
the material‘s ability to slide
• cleaning
overvIew
A
R
F
“R” position = reverse gear (must be held in
this position).
This setting is required for:
• relieving pressure on the mortar hose
• suction unit disassembly
Detailed explanation of selector switch use:
If the selector switch is in the “A” position, the PowrPlast 600
can be switched on and off with the material shut-off on the
automatic or pneumatic spray lance.
If there is no spray lance fitted (e.g.: assembly/disassembly of
suction unit), the machine is switched on using the “F” switch
position and off using the “A” position.
Since the air supply through the compressor needs to be
switched off to clean the mortar hose, the pneumatic lance
is not controlled using the material shut-off. In this case, the
machine must therefore also be switched on using the “F” po-
sition.
Important: control via the selector switch and
material shut-off are treated equally.
The machine can be switched from the “A” po-
sition (control using material shut-off) to “F” at
any time.
We would therefore recommend that only one
person operate the machine.
The operating light (green, Fig. 3, 4) indicates that the machine
is energised and ready.
When the mains plug is connected the PowrPlast 600 carries
out a function check. While this is going on the indicator light
(red, fig. 3.3) flashes. If everything is in working order, the flash
-
ing stops after about 30 seconds. If the indicator light lights up
during operation, this indicates that there is a malfunction. For
detailed information about this kind of fault, refer to the „Rec-
tification of faults“ section on page 47.
If the selector switch is in the “F” position when
the mains plug is plugged in, the machine will not
switch on.
Briefly move selector switch to “A” and then back
to “F” to switch on the machine.
eMeRGeNcy StOP switch
When the EMERGENCY STOP switch is pressed, the PowrPlast
600 is switched off immediately.
Turn the EMERGENCY STOP switch in order to release it again.
The machine remains switched off after release. To switch it on
again, the selector switch must be briefly set to “A” and then
to “F”.
2
A
F
R
POWER
ERROR
1
4
3
5