39
PowrPlast 600
GB
6
cOMMISSIONING
6.1
INStALLAtION LOcAtION
The mortar spraying machine and the bucket from which the
material to be processed is to be pumped have to be set up on
an even and firm underground. This ensures that the machine
and bucket cannot slide away or fall over.
6.2
INItIAL StARtING-uP
6.2.1
ScOPe OF SuPPLy
The machine is supplied by the manufacturer in the following
individual components:
• Complete basic machine comprising drive unit, control unit
and transport frame with wheels
•
Pump unit complete
• Tool : Special key
•
Hose package
• Spray lance
•
Pump sliding means
6.2.2
ASSeMBLy
Pull safety pin (1) to rear to release lock. Pull PowrPlast 600 up
by its frame (2) until the machine engages in the top position.
Spray rotor (3) with a suitable pump lubricant (order no. 9992
824).
Move selector switch (4) to “A” and set delivery volume con
-
troller (5) to „0“.
Connect mains plug to mains power supply.
The operation light (6) shows operational readiness.
The red indicator light (7) flashes during the function check
commIssIonIng
• Before connecting the unit to the mains supply, ensure that
the line voltage matches that specified on the rating plate.
Min. wire cross-section 3 x 1.5 mm
2
. Unroll the
extension cable completely. Ensure that the
coupling pieces and plugs are free of dam-
age.
Lay the device supply cable so that there is no
danger of stumbling.
Protect against damage, for example against
being driven over.
6.1.1
cONNectION tO MAINS POWeR SuPPLy/
exteNSION cABLe
connection to the mains network only via a special feed-
ing point, for example via a distribution board for con-
struction sites, with residual current protective device
with INF
≤
30 mA.
for about 30 seconds.
Fold locking pins (8) up towards the magnet holders in the
handle to prevent them being twisted during assembly.
Only the person controlling the machine
may assemble the pump unit.
Never operate mortar spraying machine
with an exposed rotor.
Do not reach into the rotor when it is
moving. Risk of crushing.
caution if you have long hair. Only wear
close-fitting clothes at work.
Slide pump unit (9) over rotor (3) from below and press up-
wards.
Set delivery volume controller (5) to 1 or 2.
Set selector switch (4) to “F” to switch on pump. The pump unit
is automatically drawn up by the rotor.
As soon as the pump unit is in its end position, fold the two
locking pins (8) down and use nuts to fix the pump unit.
If necessary rotate pump unit (9) by hand to
move locking pins (8) into end position.
Set selector switch (4) to “A” to switch off pump.
Disconnect mains plug.
After assembling the pump unit, secure the
union nut (10) on the pump unit, using the
special key to do so.
A
F
R
POWER
ERROR
4
6
2
1
3
A
F
R
POWER
ERROR
5
8
9
10
7