background image

2

 

USAGE

1. 

Perform the startup procedure on the main unit (refer to the main unit 

operation manual).  

2. 

Once the system is on and the compressor is running, return to the spray 

gun and open the air valve.  Ensure that air is flowing out of the nozzle.

Attention

Never trigger the spray gun without air supply on.  Doing so 

will significantly reduce the life of the nozzle and spray gun.  

3. 

Once the system has achieved the desired pressure and heat settings 

(refer to the main unit operation manual and material manufacturer’s 

temperature recommendations) the A and B side material inlet valves 

can now be opened.  

4. 

The system is now ready to spray.  The gun will not spray until the trigger 

and trigger safety are depressed at the same time.  This can be achieved 

by making sure the user’s hand is gripping the trigger while at the same 

time setting the trigger safety within the user’s palm.  

Attention

Damage to the spray gun may result when used with an air 

pressure lower than 30 PSI.

i

The spray gun trigger will be locked (it will not spray) as long 

as the trigger safety is not depressed. 
It is recommended that the sprayer be tested on a scrap piece 

of cardboard somewhere outside of the immediate intended 

spray area.  

4.1 

CHANGING THE NOZZLE

i

Nozzle performance is something that can be felt and seen 

very easily.  A new nozzle should produce approximately 300 

cycles per minute (CPM) spraying performance.
Once the Helix LP is linked and ready to spray, press #4 on 

the A side control panel.  This will display the cycle rate.  This 

range can vary with material and temperature.
When the cycle rate drops about 10%, a change in 

performance should be noticeable, requiring a slower 

spraying movement.    The cycle rate will gradually decrease 

as the nozzle usage increases.
At approximately 100-120 cycles per minute (CPM) 

applicators may find that spraying movement speed is too 

slow and replace the nozzle. 

i

The main unit will automatically manage the pressures and 

ratio regardless of the cycle rate.  It will not be necessary to 

make any system adjustments.
If any leakage is noticeable at the spray gun, immediately 

stop spraying, close all ball valves on the whip hoses, and 

replace the spray gun.

PARTS LIST

Part No.

Description

Gun 

Qty.

Round 

Nozzle 

Qty.

2405674

PROPURGE™ gun and nozzle kit

1

15

0153951

PROPURGE™ gun kit

1

------

0153952

Round Maze Nozzle™ kit

------

25

Not included, available for separate purchase (see graphic below):
0153979

Ball valve

0138982

Whip hose (blue)

0138983

Whip hose (red)

0138982

0153979

0153979

0153979

0138983

EU Declaration of conformity

We declare under sole responsibility that this product conforms 

to the following relevant stipulations:  

2006/42/EC, 2011/65/EU
Applied harmonised norms:  

EN ISO 12100, EN 1953
The EU declaration of conformity is enclosed with the product.  

If required, it can be re-ordered using order number 2399726.

Reviews: