background image

© Titan Tool Inc.  All rights reserved. 

7

 

 

  3.  Move the PRIME/SPRAY valve up to the 

SPRAY position.

  4.  Turn the pressure control knob clockwise to 

its highest setting.  The paint hose should 

stiffen as paint begins to flow through it.

  5.  Unlock the gun trigger lock.

  6.  Trigger the spray gun to bleed air out of the hose.

  7.  When paint reaches the spray tip, spray a test area to 

check the spray pattern.

Good spray pattern

Paint tailing pattern

  8.  Use the lowest pressure setting 

necessary to get a good spray 

pattern.  If the pressure is set 

too high, the spray pattern will 

be too light.  If the pressure is 

set too low, tailing will appear 

or the paint will spatter out 

in gobs rather than in a fine 

spray.

cleanup

Do not use gasoline to clean the sprayer.

Special cleanup instructions for use with 

flammable solvents:

  •  Always flush spray gun preferably outside and at least one 

hose length from spray pump.

  •  If collecting flushed solvents in a one gallon metal 

container, place it into an empty five gallon container, then 

flush solvents.

  •  Area must be free of flammable vapors.

  •  Follow all cleanup instructions.

IMPORTaNT:  The sprayer, hose, and gun should be cleaned 

thoroughly after daily use.  Failure to do so permits material 

to build up, seriously affecting the performance of the unit.

always spray at minimum pressure with the gun 

nozzle tip removed when using mineral spirits or 

any other solvent to clean the sprayer, hose, or 

gun.  Static electricity buildup may result in a fire 

or explosion in the presence of flammable vapors.

  1.  Follow the “Pressure Relief Procedure” found in the 

Operation section of this manual.

  2.  Remove the gun tip and tip guard and clean with a brush 

using the appropriate solvent.

  3.  Place the siphon tube into a container of the appropriate 

solvent.  Examples of the appropriate solvent are water for 

latex paint or mineral spirits for oil-based paints.

  4.  Place the return hose into a metal waste container.

  5.  Set the pressure to minimum by turning the pressure 

control knob fully counterclockwise.

  6.  Move the PRIME/SPRAY valve down to 

the PRIME position.

NOTE:   hold the return hose in the waste 

container when moving the PRIME/

SPRay valve to PRIME in case the 

sprayer is pressurized.

  7.  Turn on the sprayer by moving the ON/OFF switch to the 

ON position.

  8.  Allow the solvent to circulate through the sprayer and 

flush the paint out of the return hose into the metal waste 

container.

  9.  Turn off the sprayer by moving the ON/OFF 

switch to the OFF position.

  10.  Move the PRIME/SPRAY valve up to its 

SPRAY position.

  11.  Turn on the sprayer.

Ground the gun by holding it 

against the edge of the metal 

container while flushing.  Failure to 

do so may lead to a static electric 

discharge, which may cause a fire.

  12.  Trigger the gun into the metal waste container until the 

paint is flushed out of the hose and solvent is coming out 

of the gun.

  13.  Continue to trigger the spray gun into the waste container 

until the solvent coming out of the gun is clean.

NOTE:   For long-term or cold weather storage, pump 

mineral sprits through the entire system.

  14.  Follow the “Pressure Relief Procedure” found in the 

Operation section of this manual.

  15.  Unplug the unit and store in a clean, dry area.

IMPORTaNT:  Do not store the unit under pressure.

cleaning the Spray Tip

  1.  Flush the gun with solvent immediately after the work is 

completed. 

  2.  Oil the sliding pins to prevent them from seizing up.
Should the spray tip become clogged, reverse the 

spray tip with the lever and pull the trigger.  Once 

the obstruction comes out of the spray tip, release 

the trigger, reverse the spray tip back to the spray 

pattern setting, and resume spraying.

Do not attempt to clean the tip with 

your finger.  

Do not use a needle or other sharp pointed 

instrument to clean the tip.  The hard tungsten 

carbide is brittle and can be chipped.

Maintenance

Before proceeding, follow the Pressure Relief 

Procedure outlined previously in this manual.  

additionally, follow all other warnings to reduce 

the risk of an injection injury, injury from moving 

parts or electric shock.  always unplug the sprayer 

before servicing!

General Repair and Service Notes

  1.  Before repairing any part of the sprayer, read the 

instructions carefully, including all warnings.

IMPORTaNT:  Never pull on a wire to disconnect it. Pulling 

on a wire could loosen the connector from the wire.

  2.  Test your repair before regular operation of the sprayer 

to be sure that the problem is corrected.  If the sprayer 

does not operate properly, review the repair procedure to 

determine if everything was done correctly.  Refer to the 

Troubleshooting section to help identify other possible 

problems.

  3.  Make sure that the service area is well ventilated in 

case solvents are used during cleaning.  Always wear 

protective eyewear while servicing.  Additional protective 

equipment may be required depending on the type of 

cleaning solvent.  Always contact the supplier of solvents 

for recommendations.

  4.  If you have any further questions concerning your Titan 

Airless Sprayer, call Titan:

 

Technical Service (U.S.) .......................

1-800-526-5362

 

 

Fax  ................................................

1-800-525-9501

Summary of Contents for RentSpray 400

Page 1: ...ent before reading this manual RentSpray 400 Airless Sprayer Model Number 0552053 0711 Titan Tool Inc All Rights Reserved Form No 0552838D NOTE This manual contains important warnings and instructions...

Page 2: ...injury as soon as possible DO NOT delay treatment to research toxicity Toxicity is a concern with some coatings injected directly into the blood stream Consultation with a plastic surgeon or reconstr...

Page 3: ...doing Do not operate the unit when fatigued or under the influence of drugs or alcohol For electric units Always unplug cord from outlet before working on equipment Do not use the hose as a strength...

Page 4: ...he gun and one on the hose tighten securely NOTE Do not attach the tip to the spray gun yet Remove the tip if it is already attached Make sure all airless hoses and spray guns are electrically grounde...

Page 5: ...solvent to paint Be sure to follow the pressure relief procedure when shutting down the sprayer for any purpose including servicing or adjusting any part of the spray system changing or cleaning spra...

Page 6: ...the gun closer to the surface deposits more paint on the surface and produces a narrower spray pattern Holding the gun farther from the surface produces a thinner coat and wider spray pattern If runs...

Page 7: ...ing the ON OFF switch to the OFF position 10 Move the PRIME SPRAY valve up to its SPRAY position 11 Turn on the sprayer Ground the gun by holding it against the edge of the metal container while flush...

Page 8: ...e gun head 6 Slide the handle over the handle tube and reattach it to the gun head 7 Secure the trigger guard back in position on the bottom of the handle NOTE For more detail part number information...

Page 9: ...hroud with the two fan shroud screws 9 Slide the motor cover over the motor Secure the motor cover with the four motor cover screws Replacing the Gears 1 Perform the Pressure Relief Procedure and unpl...

Page 10: ...edures to service the valves and repack the fluid section Perform the following steps before performing any maintenance on the fluid section 1 Loosen and remove the four front cover screws Remove the...

Page 11: ...wer packings Refer to the illustration below for proper packing orientation Install lower packings with raised lip and O ring facing up Install upper packing with raised lip and O ring facing down O R...

Page 12: ...set connection and tighten or re tape the connection with tape 3 Remove the pump filter element and clean Remove the inlet screen and clean 4 Remove the siphon tube suction set and clean 1 Replace the...

Page 13: ...Titan Tool Inc All rights reserved 13 Notes...

Page 14: ...n ou un sp cialiste en chirurgie reconstructive de la main DANGER MANATIONS DANGEREUSES Certains produits peintures solvants insecticides ou autres peuvent tre nocifs s ils sont inhal s ou entrent en...

Page 15: ...grands vents Porter des v tements aptes prot ger la peau et les cheveux du produit utilis Ne pas utiliser le pistolet ou ne pas pulv riser de produits en pr sence d enfants proximit loigner les enfant...

Page 16: ...os revestimientos inyectados directamente en la corriente sangu nea Puede ser aconsejable consultar con un cirujano pl stico o un cirujano especialista en reconstrucci n de las manos PELIGRO VAPORES P...

Page 17: ...en todo momento No se asome ni se pare sobre soportes inestables Mantenga siempre la posici n firme y el equilibrio efectivos Use la presi n m s baja posible para enjuagar el equipo Mant ngase alerta...

Page 18: ...cart only 2 9 0507783 Hose clip upright cart only 1 10 0508552 Siphon tube upright cart only 1 11 0551556 Return hose upright cart only 1 12 5006536 Inlet screen upright cart only 1 Item Part Descrip...

Page 19: ...9 Return hose 1 3 0279459 Hose clip 1 4 0295565 Inlet screen 1 5 9871105 O ring 2 6 9822526 Retaining ring 1 7 9850638 Tie wrap 2 Labels Part Description 0552834 Logo label front 0552836 Logo label si...

Page 20: ...Tool Inc All rights reserved Gear Box Assembly 1 2 3 4 5 9 10 11 12 13 14 15 16 17 18 6 7 8 19 18 20 21 22 23 25 24 26 27 28 NOTE All electrical work should be performed by a Titan authorized service...

Page 21: ...0 Ground screw 1 17 0551112 Transducer assembly includes o ring 1 18 0551515 Circuit breaker 1 19 9850936 ON OFF switch 1 20 03662 Microswitch insulator 1 21 0295490 Microswitch 1 22 9800604 Screw 2 2...

Page 22: ...nlet valve ball 1 18 0551534 Inlet valve seat 1 19 0509582 O ring 1 20 0508680 Inlet valve housing stand and low boy cart 1 0508690 Inlet valve housing upright cart 21 0551532 Filter assembly includes...

Page 23: ...elay Capacitor Motor WHITE BLACK BLACK BLACK RED RED 90 Female Quick Connect Male Female Piggyback Female Quick Connect P N 0551496 P N 0551497 P N 0507974 P N 0551498 P N 0508650 P N 0295418 P N 0507...

Page 24: ...71 Lubriplate contenant d environ 400 g 14 oz 314 172 Lubriplate contenant d environ 3 kg 6 lb 0521010 Paint Renew starter kit 0521523 Paint Renew 1 gallon de recharge 0297055 Bouclier de pompe Pump S...

Page 25: ...malla 60 Las amplitudes de abanico entre 8 y 12 pulgadas 20 a 30 cm son preferibles porque ofrecen m s control al rociar y es menos probable que causen obstrucciones Protector l quido Liquid Shield Li...

Page 26: ...PR SENTES TITAN SE D GAGE DE TOUTE AUTRE GARANTIE IMPLICITE INCLUANT SANS TOUTEFOIS S Y LIMITER LES GARANTIES DE COMMERCIABILIT ET D ADAPTATION UN USAGE PARTICULIER DANS LES LIMITES PERMISES PAR LA LO...

Page 27: ...nidad de tal modo que se vea afectado el funcionamiento normal Las piezas defectuosas deben devolverse a un centro de ventas y servicio autorizado de Titan Todos los cargos de transporte incluso la de...

Page 28: ...NOT LIMITED TO THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT PERMITTED BY LAW THE DURATION OF ANY IMPLIED WARRANTIES WHICH CANNOT BE DISCLAIMED IS LIMITED TO THE TIME PER...

Reviews: