Servicing the Fluid Section

Use the following procedures to service the valves and repack
the fluid section.  Perform the following steps before
performing any maintenance on the fluid section.

1. Loosen and remove the four front cover screws.  Remove

the front cover.

2. Stop the sprayer at the bottom of its stroke so that the

piston is in its lowest position.  Turn off and unplug the
sprayer.

3. Perform the Pressure Relief Procedure and unplug the

sprayer.

Before proceeding, follow the Pressure Relief
Procedure outlined previously in this manual.
Additionally, follow all other warnings to reduce
the risk of an injection injury, injury from moving
parts or electric shock.  Always unplug the
sprayer before servicing!

4. Unscrew the return hose assembly from the pump block.
5. Remove the retaining clip that holds the suction set in the

foot valve.  Pull the suction set out of the foot valve.

6. Tilt the pump back for easy access to the fluid section.

Servicing the Valves

The design of Titan's fluid section
allows access to the foot valve and
seat as well as the outlet valve and
seat without completely
disassembling the fluid section.  It
is possible that the valves may not
seat properly because of debris
stuck in the foot valve seat or outlet
valve seat.  Use the following
instructions to clean the valves and
reverse or replace the seats.

1. Using a wrench, loosen and

remove the foot valve housing
from the pump block.

2. Clean out any debris in the foot valve housing and

examine the valve housing and seat.  If the seat is
damaged, reverse or replace the seat.

3. Using a 3/4" socket wrench, loosen and remove the outlet

valve retainer from the piston rod. 

4. Clean out any debris and

examine the outlet valve retainer
and seat.  If the seat is damaged,
reverse or replace the seat.

5. Remove, clean, and inspect the outlet cage, crush

washer, and outlet valve ball.  Replace if they are worn or
damaged.

6. Reassemble the valves by reversing the steps above.

NOTE: During reassembly of the outlet valve, apply

one drop of Loctite (included in the repacking
kit) to the threads of the outlet valve retainer
before threading it into the piston rod.  Then,
torque the retainer to 144 in./lbs. (12 ft./lbs.).

NOTE: Always service the

outlet valve with the
piston rod attached to
the pump.  This will
prevent the piston rod
from rotating during
disassembly of the
outlet valve.

Outlet Valve 

Retainer

Outlet Valve 

Seat

Outlet Valve 

Ball

Outlet Cage

Crush Washer

Piston Rod

Foot Valve 
Housing

Foot Valve 
Seat

Foot Valve 
Ball

Bushing

O-Ring

Lower Cage

Lower Seal

10

© Titan Tool Inc.  All rights reserved.

Repacking the Fluid Section

1. Remove the foot valve and outlet valve assemblies using

the steps in the “Servicing the Valves” procedure above.

2. Using 3/8” a hex

wrench, loosen and
remove the two
pump block
mounting screws.

3. Pull the pump block

down approximately
1/2” from the pump
housing.

4. Slide the pump block

and piston rod
forward until the
piston rod is out of
the T-slot on the
connecting rod.

5. Slide the piston rod

out through the
bottom of the pump
block.

6. Loosen and remove

the retainer nut and
piston guide from the
pump block.

7. Remove the upper

and lower packings from the pump block.

8. Clean the pump block and install the new upper and lower

packings.  Refer to the illustration below for proper
packing orientation.

9. Inspect the piston rod for wear and replace if necessary.

10. Reassemble the outlet valve assembly into the piston rod.

Tighten the outlet valve retainer with a wrench until secure.

IMPORTANT:  Never use a wrench on the piston itself.
This could cause damage to the piston and cause leakage.

11. Insert the piston guide into the retainer nut.  Thread the

retainer nut into the pump block until it is hand tight.

12. Slide the piston guide tool (included in the repacking kit)

over the top of the piston rod and insert the piston rod
through the bottom of the pump block.  Using a rubber
mallet, tap the bottom of the piston rod lightly until the
piston rod is in position in the pump block.

13. Using a wrench, tighten the retainer nut securely.
14. Slide the top of the piston rod into the T-slot on the

connecting rod.

NOTE: Coat the piston guide tool and the piston rod

with grease before inserting them into the
pump block.

NOTE: Use the T-slot on the connecting rod to hold

the piston rod in position while securing the
outlet valve retainer.

Install lower packings 

with raised lip and O-ring 

facing up.

Install upper packing 

with raised lip and O-ring 

facing down.

O-Ring

O-Ring

Raised Lip

Raised Lip

Connecting 

Rod

Retainer 

Nut

Piston 

Guide
Upper 

Packing

Pump 

Block

Lower  

Packings

Pump Block 

Mounting 

Screw

Piston Rod

T-Slot

NOTE: The outlet valve does not need to be

disassembled from the piston rod for this
procedure.

Summary of Contents for RentSpray 450

Page 1: ...re reading this manual RentSpray 450 Airless Sprayer Owner s Manual For professional use only NOTE This manual contains important warnings and instructions Please read and retain for reference NOTE Th...

Page 2: ...injected directly into the blood stream Consultation with a plastic surgeon or reconstructive hand surgeon may be advisable HAZARD HAZARDOUS VAPORS Paints solvents insecticides and other materials ca...

Page 3: ...s Always unplug cord from outlet before working on equipment Do not use the hose as a strength member to pull or lift the equipment Do not lift by cart handle when loading or unloading Grounding Instr...

Page 4: ...e gun and one on the hose tighten securely Make sure all airless hoses and spray guns are electrically grounded and rated at or above the maximum operating pressure range of the airless sprayer 4 Make...

Page 5: ...at the spray gun does not have a tip or tip guard installed NOTE Hold the return hose in the waste container when moving the PRIME SPRAY valve to PRIME in case the sprayer is pressurized NOTE Incompat...

Page 6: ...be applied without runs or sags Holding the gun closer to the surface deposits more paint on the surface and produces a narrower spray pattern Holding the gun farther from the surface produces a thinn...

Page 7: ...o a metal waste container 5 Move the PRIME SPRAY valve down to its PRIME position 6 Set the pressure to minimum by turning the pressure control knob fully counterclockwise 7 Turn on the sprayer by mov...

Page 8: ...NOTE Rotate the motor fan manually until the armature gear engages with the mating gear in the pump housing NOTE If the motor will not dislodge from the pump housing Remove the front cover plate Using...

Page 9: ...the hole in the pump block during reassembly Improper alignment may cause damage to the transducer o ring Front Cover Pump Housing Front Cover Screw 2nd Stage Gear Thrust Washer Motor Gear and Crank...

Page 10: ...ump This will prevent the piston rod from rotating during disassembly of the outlet valve Outlet Valve Retainer Outlet Valve Seat Outlet Valve Ball Outlet Cage Crush Washer Piston Rod Foot Valve Housi...

Page 11: ...the new or cleaned filter into the pump block 5 Slide the filter housing over the filter and thread it into the pump block until secure Pump Block Seal Filter Filter Housing NOTE Left handed threads r...

Page 12: ...wing the Servicing the Fluid Section procedure in the Maintenance section of this manual 10 Take sprayer to a Titan authorized service center 1 Repack the pump following the Servicing the Fluid Sectio...

Page 13: ...ith a minimum of 50 x 1 4 grounded textile braid airless paint spray hose 2 Replace the spray tip following the instructions that came with the spray gun 3 Rotate the pressure control knob countercloc...

Page 14: ...n ou un sp cialiste en chirurgie reconstructive de la main DANGER MANATIONS DANGEREUSES Certains produits peintures solvants insecticides ou autres peuvent tre nocifs s ils sont inhal s ou entrent en...

Page 15: ...ents Porter des v tements aptes prot ger la peau et les cheveux du produit utilis Ne pas utiliser le pistolet ou ne pas pulv riser de produits en pr sence d enfants proximit loigner les enfants de l q...

Page 16: ...tos revestimientos inyectados directamente en la corriente sangu nea Puede ser aconsejable consultar con un cirujano pl stico o un cirujano especialista en reconstrucci n de las manos PELIGRO VAPORES...

Page 17: ...del equipo en todo momento No se asome ni se pare sobre soportes inestables Mantenga siempre la posici n firme y el equilibrio efectivos Use la presi n m s baja posible para enjuagar el equipo Mant n...

Page 18: ...ty 1 704 181 Screw 4 2 766 232 Motor cover 1 3 Motor assembly 1 4 704 179 Left leg assembly 1 5 761 178 Screw 4 6 766 115 Fluid section assembly 1 Item Part Description Quantity 7 704 117 Screw 2 8 Ge...

Page 19: ...2 6 704 322 Shroud screw 2 Item Part Description Quantity 7 704 277 Motor 120V complete includes items 1 5 6 10 and 11 1 8 704 258 Y adapter positive red 1 9 704 331 Gasket 1 10 704 250 Motor fan 1 11...

Page 20: ...20 Titan Tool Inc All rights reserved Gear Box Assembly 2 1 10 11 8 9 13 12 14 15 17 16 18 19 20 21 3 24 1 26 27 1 28 25 22 23 4 5 6 7...

Page 21: ...21 704 323 Screw 1 22 704 169 MIcroswitch mounting plate 1 23 704 125 Washer 2 24 700 785 Lock washer 2 25 704 380 ON OFF switch 1 26 704 211 Circuit breaker 1 27 704 363 Capacitor rectifier kit inclu...

Page 22: ...24 23 27 28 29 30 31 32 33 34 35 36 Install lower packings with raised lip and O ring facing up Install upper packing with raised lip and O ring facing down O Ring O Ring Raised Lip Raised Lip NOTE P...

Page 23: ...fan width required for a specific job and by the orifice size that will supply the desired amount of fluid and accomplish proper atomization For light viscosity fluids smaller orifice tips generally a...

Page 24: ...s not apply in the case of damage or wear caused by abrasion corrosion or misuse negligence accident faulty installation substitution of non Titan component parts or tampering with the unit in a manne...

Reviews: