1
—
Installation of the UMAP 2110
1.2.3 Power and Ground Connections
Figure 1-4 DC Power connection and power switch of UMAP 2110
DC Power Connections
The DC power interface is a 4-pin terminal block with polarity signs on the front panel of the
DSLAM.
The UMAP 2110 can be powered from two –48V DC power supply. The DC power connector is a
4P terminal block; 2P is for accommodating one DC power input and other 2P is for accommo-
dating another DC power input. The DC power should be connected to a well-fused power supply.
After completing chassis installation, please apply power to the fused power distribution panel
feeding the chassis. When using a DC voltmeter, please check for proper voltage: -60V ~ -36V DC,
and make sure that the polarity is correct.
Warning —
Ensure that all power sources to the chassis (power distribution panel) are turned off
during the connection.
Note —
It is recommended that the -48VDC power be supplied directly and independently by a
power feeding system and also avoid having a parallel or mutual connection with other
-48VDC power supplier of telecom equipment. This is to guarantee our products against
interferences by other equipment while they are working.
8 / 54
Summary of Contents for UMAP 2110
Page 2: ......
Page 10: ...2 54 ...
Page 28: ...1 Installation of the UMAP 2110 20 54 ...
Page 33: ...1 Installation of the UMAP 2110 Fail to Get File 25 54 ...
Page 43: ...1 Installation of the UMAP 2110 35 54 ...
Page 44: ...1 Installation of the UMAP 2110 36 54 ...
Page 60: ...52 54 ...
Page 61: ...53 54 ...
Page 62: ......