The following steps must be taken before the first start: 
 

 

Fill up hydraulic fluid

 (e.g. ISO VG 46) at the filler pipe if necessary until 

the oil gauge is filled with oil 

 

Connect the plug

 to a power source (Consider the electrical data) 

 

Disconnect all hoses

 to the consumers 

 Close 

the 

manual shut-off valve

 (otherwise pressure-free circulation) 

 

Adjust the working pressure 

at the pressure limiting valve

 

 

 

Build up the pressure

 by operating the tracer 

  

 Stop 

building up the pressure 

by releasing the tracer 

 

 

Release

 

the pressure 

by opening the manual shut-off valve or by 

operating the tracer 

 

 

 

CAUTION: ALWAYS CHECK THE MAX. ADJUSTED HYDRAULIC 
PRESSURE FIRST WITHOUT THE HOSES OR TOOLS CONNECTED.  
THE MAX. PERMISSIBLE HYDRAULIC PRESSURE OF THE SUPPLIED 
HYDRAULIC GAUGE MUST NOT BE EXCEEDED. 
 
TURN THE REGULATING KNOB COUNTERCLOCKWISE 

 REDUCES THE 

PRESSURE 
 
TURN THE REGULATING KNOB CLOCKWISE 

 INCREASES THE 

PRESSURE 

 
Always observe the hydraulic pressure gauge when applying pressure to the 
pump. 

Safety requires that you read very carefully and understand fully the operation 
instructions, prior to turning on and operating the pump.

Summary of Contents for WindMaster 2010

Page 1: ...tional Inc 9001 Jameel Street Suite 180 Houston TX 77040 Toll Free 866 345 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Operating Manual TITAN WindMaster 2010...

Page 2: ...sales titanti com http www titanti com Contents Contents 2 Signs and symbols 3 Before starting 4 Starting 5 Pressure adjustment 6 Venting 7 Coupling of the high pressure hoses 7 Safety hints 9 Short g...

Page 3: ...5 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Signs and symbols Attention Attention Slipping Hazard Attention Overhead Hazard Command High Importance Command...

Page 4: ...to ensure the optimum function and a high degree of safety The equipment is delivered fully assembled functionally tested vented and filled with hydraulic oil To prevent the oil from spilling during...

Page 5: ...RS SHOULD BE USED CHECK ALL HOSES FOR KINKING AND IF FOUND REPLACE PRIOR TO PRESSURIZING FOR BEST RESULTS AND OPTIMUM SAFETY USE ONLY TITAN SUPPLIED HOSES CONNECTIONS AND ACCESSORIES ATTENTION NEVER U...

Page 6: ...ssary wear and thermal loads on the device Do not touch the motor and parts near the motor after using it since the surfaces can be hot Pressure adjustment The output consumer pressure can be determin...

Page 7: ...without bubbles Make the desired pressure adjustment Chap Pressure adjustment Coupling of the high pressure hoses CAUTION IT IS VERY IMPORTANT THAT THE TWO HALVES OF THE COUPLING ARE ALWAYS CLEANED TH...

Page 8: ...com Handling instruction for the heating mechanism Heater Fig 3 Switch box heater Switch on the Power supply By pressing the heating button see Fig 3 the pump runs one minute in a pressure free circul...

Page 9: ...and the general drawing Changes to the functional sequence or a different application are not allowed It must always check if the high pressure hoses are connected correctly The high pressure hoses m...

Page 10: ...g pressure at the pressure limiting valve Build up the pressure by operating the tracer Stop building up the pressure by releasing the tracer Release the pressure by opening the manual shut off valve...

Page 11: ...k It is only necessary to release the lid fastening screws on the unit and the entire pump motor unit can be removed Then rinse out the oil tank with oil only DO NOT USE TEXTILES The suction filter of...

Page 12: ...urize Air in pump Switch motor on and off several times Changeover valve jammed Switch by hand Pressure converter defective Replacement necessary Pump pressurizes inadequately Air in pump Switch motor...

Page 13: ...on Position Y1 Pressure increases Position Y2 Pressure decreases Central position Pressure free circulation 6 Hydraulic delockable check valve HRV1 Function Opens with the manipulation of the directio...

Page 14: ...Function The pump runs one minute in a pressure free circulation to warm up the Oil 11 General Weight incl oil Approx 35 kg type dependent Dimensions mm HxWxL 525x360x585 Tank capacity Approx 3 l carr...

Page 15: ...AN Technologies International Inc 9001 Jameel Street Suite 180 Houston TX 77040 Toll Free 866 345 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Hydraulic schema...

Page 16: ...AN Technologies International Inc 9001 Jameel Street Suite 180 Houston TX 77040 Toll Free 866 345 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Electric schemat...

Page 17: ...reet Suite 180 Houston TX 77040 Toll Free 866 345 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Appendix Before starting the plug has to be replaced by the vent...

Reviews: