background image

 

TITAN Technologies International, Inc.

® 

9001 Jameel Street,  Suite 180 •  Houston, TX 77040 

Toll-Free: 866.345.8484 • Phone: 281.449.9994 • Fax: 281.449.9996 • Email:sales@titanti.com   

http://www.titanti.com 

Safety hints 

 

Apart from observing the general accident prevention regulations, the following 
safety instructions must be observed to prevent life-endangering conditions, 
damage and an increased accident hazard. 

 

If leaks occur when pressure is applied,

 the pressure must be relieved 

immediately. The leak must be sealed and defective components must be 
replaced. 
 

When repairs are made

 use original spare parts only. The unauthorised 

replacement of damaged components with non-original spare parts is not 
permitted. 
 
All components

 must be handled exclusively as described in the 

operating instructions and the general drawing. Changes to the 
functional sequence or a different application are not allowed. 
 

It must always check if the

 high-pressure hoses

 are connected correctly. 

 
The 

high-pressure hoses

 must be laid such that they cannot be driven 

over by vehicles or unnecessarily trodden by persons. Never lay hoses over 
sharp objects (danger of cutting) and do not pinch or trap them. 
 
Before the pressure is applied, the maximum working pressure (without 
consumers) must be adjusted 

by an authorised person 

at the 

pressure-

limiting valve

 (Chap. Pressure adjustment). 

 
The unit is 

not fitted with a safety valve

. The maximum system pressure 

of 2500 bar must never be exceeded. 
 

Repairs

 must only be conducted when the system is depressurised and 

disconnected from the power. 
 
Verify the 

oil level

 before each commissioning. 

 

You must carry protection eyeglasses while working with high-pressure 
hydraulic aggregates. 
 
In the case of use of a remote control, pay attention to electromagnetic 
radiations. 

Summary of Contents for WindMaster 2010

Page 1: ...tional Inc 9001 Jameel Street Suite 180 Houston TX 77040 Toll Free 866 345 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Operating Manual TITAN WindMaster 2010...

Page 2: ...sales titanti com http www titanti com Contents Contents 2 Signs and symbols 3 Before starting 4 Starting 5 Pressure adjustment 6 Venting 7 Coupling of the high pressure hoses 7 Safety hints 9 Short g...

Page 3: ...5 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Signs and symbols Attention Attention Slipping Hazard Attention Overhead Hazard Command High Importance Command...

Page 4: ...to ensure the optimum function and a high degree of safety The equipment is delivered fully assembled functionally tested vented and filled with hydraulic oil To prevent the oil from spilling during...

Page 5: ...RS SHOULD BE USED CHECK ALL HOSES FOR KINKING AND IF FOUND REPLACE PRIOR TO PRESSURIZING FOR BEST RESULTS AND OPTIMUM SAFETY USE ONLY TITAN SUPPLIED HOSES CONNECTIONS AND ACCESSORIES ATTENTION NEVER U...

Page 6: ...ssary wear and thermal loads on the device Do not touch the motor and parts near the motor after using it since the surfaces can be hot Pressure adjustment The output consumer pressure can be determin...

Page 7: ...without bubbles Make the desired pressure adjustment Chap Pressure adjustment Coupling of the high pressure hoses CAUTION IT IS VERY IMPORTANT THAT THE TWO HALVES OF THE COUPLING ARE ALWAYS CLEANED TH...

Page 8: ...com Handling instruction for the heating mechanism Heater Fig 3 Switch box heater Switch on the Power supply By pressing the heating button see Fig 3 the pump runs one minute in a pressure free circul...

Page 9: ...and the general drawing Changes to the functional sequence or a different application are not allowed It must always check if the high pressure hoses are connected correctly The high pressure hoses m...

Page 10: ...g pressure at the pressure limiting valve Build up the pressure by operating the tracer Stop building up the pressure by releasing the tracer Release the pressure by opening the manual shut off valve...

Page 11: ...k It is only necessary to release the lid fastening screws on the unit and the entire pump motor unit can be removed Then rinse out the oil tank with oil only DO NOT USE TEXTILES The suction filter of...

Page 12: ...urize Air in pump Switch motor on and off several times Changeover valve jammed Switch by hand Pressure converter defective Replacement necessary Pump pressurizes inadequately Air in pump Switch motor...

Page 13: ...on Position Y1 Pressure increases Position Y2 Pressure decreases Central position Pressure free circulation 6 Hydraulic delockable check valve HRV1 Function Opens with the manipulation of the directio...

Page 14: ...Function The pump runs one minute in a pressure free circulation to warm up the Oil 11 General Weight incl oil Approx 35 kg type dependent Dimensions mm HxWxL 525x360x585 Tank capacity Approx 3 l carr...

Page 15: ...AN Technologies International Inc 9001 Jameel Street Suite 180 Houston TX 77040 Toll Free 866 345 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Hydraulic schema...

Page 16: ...AN Technologies International Inc 9001 Jameel Street Suite 180 Houston TX 77040 Toll Free 866 345 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Electric schemat...

Page 17: ...reet Suite 180 Houston TX 77040 Toll Free 866 345 8484 Phone 281 449 9994 Fax 281 449 9996 Email sales titanti com http www titanti com Appendix Before starting the plug has to be replaced by the vent...

Reviews: