Maintaining the riveting tool
Caution
Hazard of injury if handled in an improper manner! Servicing,
maintenance and repairs of the riveting tools must be carried
out professionally. On completing this work, there should not be
any more hazard to the operator, if used as per the regulations.
The operator may only carry out the operations mentioned
here.
Bleeding the hydraulic section
It is necessary to bleed the hydraulic section or to refill the hydraulic oil
when:
— oil is leaking from defective O-rings,
— after an oil-change at the time of an overhaul
(either after a maximum of 3 years, or after 2000 working hours).
Achtung
Immediately replace defective sealings. Maintenance and servi-
ce work not described in this operating manual may only be
carried out by trained specialists following instruction by
RIVETEC
on the basis of the service instructions which
also
exist. See the address on page 42 for more information on
service instructions and training.
• Detach the compressed air connection.
• Tap trigger (12): You will bleed the inside of the compressed air systems;
pistons are in a neutral position.