background image

36 
 

 

 

DIAGNOSTIC LOG FILES 

The  diagnostic  log  files  contain  information  about  the  recording  sessions  on  the  SD  card. 

Information such as temperature, battery voltage, GPS locations, settings and user interactions 

can be extracted from this file. The log file can be opened can be opened as a text file or in a 

spreadsheet application such as Microsoft Excel

 

SOFTWARE 

The Chorus comes with a free version of 

Anabat Insight

, available for download from 

www.titley-scientific.com  

Anabat Insight has the following features: 

 

View your files in full spectrum & zero crossing  

 

Use filters and scans to optimize your bat call analysis 

 

Display metrics for passes and individual bat pulses 

 

View & customize metadata  

 

Generate reports to present your analysis results 

 

Use built-in mapping to view your tracks & waypoints 

 

Export mapping data to GIS programs 

 

Listen to and view spectrograms of stereo and mono acoustic recordings.  

 

Create custom recording schedules to be used on the Chorus.  

 

CREATING SCHEDULES 

In Anabat Insight, you can create a custom schedule for your Chorus  as follows: 

1.

 

Open Anabat Insight.  Go to 

Devices

 > 

Chorus  Scheduler  Tool

. This will bring up 

the 

Schedule Manager

.  

2.

 

Click the 

+  button

 to create a new schedule task, give it a  name and choose a task 

colour. To help pre-fill some recording settings, the type of recording is surmised from 

the task name. For example, 

default  ultrasonic  microphone  settings  will  be  pre-filled.  If  the  name  contains 

-filled. 

Summary of Contents for CHORUS

Page 1: ...CHORUS User Manual Version 1 0 ...

Page 2: ...ey scientific com uk titley scientific com ask titley scientific com us www titley scientific com General Enquiries info titley scientific com AUTHORS AND ACKNOWLEDGMENTS This manual was written by Julie Broken Brow Dean Thompson We greatly appreciate the time comments and assistance given by those people who were beta testers for the Chorus and this manual The testing and troubleshooting have imp...

Page 3: ...THE CHORUS 13 STEP BY STEP GUIDE 13 TURNING THE RECORDER ON OFF SLEEP 16 UPDATING FIRMWARE 16 RECORDING MODES 17 Night Only Recording Mode 17 Dusk Dawn Recording Mode 17 Day Only Recording Mode 18 Continuous Recording Mode 18 Schedule Recording Mode 18 Selecting a Recording Mode 18 RECORDING SETTINGS 19 SAMPLE RATE FILE TYPE ACOUSTIC OR ULTRASONIC RECORDING 19 SELECT THE MICROPHONE 20 ACOUSTIC REC...

Page 4: ...mum File Time 23 10k High Pass Filter 23 GPS SETTINGS 24 TRANSECT MODE 24 CHECK LOCATION 25 OTHER SETTINGS 26 FILENAME PREFIX 26 CLOCK SCHEDULE 26 Time Zone 26 Time Format 26 Check Sunset Sunrise Times 27 RESET SETTINGS 27 RECORDER STATUS INFO 27 TESTING YOUR CHORUS 28 FLASHING STATUS ICONS OR CHECK LED 29 PASSIVE DEPLOYMENT CONSIDERATIONS 32 WEATHERPROOFING 32 MOUNTING PLACEMENT 33 EQUALIZATION C...

Page 5: ...5 DIAGNOSTIC LOG FILES 36 SOFTWARE 36 CREATING SCHEDULES 36 CHECKING SCHEDULES 42 METADATA 43 TROUBLESHOOTING FAQS 43 How do I set up the detector for ultrasonic bat recording 43 How do I set up the recorder for acoustic audible sound recording 44 FURTHER INFORMATION 48 ...

Page 6: ... 300 hours acoustic on 4 AA batteries Built in GPS Stand alone recorder no phone apps required for setup Built in temperature sensor Automatic schedules for easy deployment or create your own custom schedule Transect mode available Analyse recordings with our free software Anabat Insight Headphone output to check microphone performance GETTING TO KNOW THE CHORUS The outside of your Chorus case has...

Page 7: ...7 EXTERNAL FEATURES ...

Page 8: ...e and time SD card free space and microphone information The four large icons in the middle of the dashboard represent the main aspects of your detector the SD card GPS microphone s and the clock You can use the left and right arrow buttons on the front of the Chorus to select one of the icons then press K button to see more information and settings ...

Page 9: ...e up and down in response to the loudness of sounds so you can see your microphones working The symbol at the top of the VU meter will indicate what type of microphone is fitted ultrasonic or acoustic In the bottom left right referring to the soft keys buttons below the screen These change to indicate what pressing the soft keys will do in different menus On the dashboard menu the left will eject ...

Page 10: ...c microphones Useable frequency response of 10kHz to 140kHz response rolls off beyond this point A note on frequency response All m at different frequencies A microphone may be sensitive at 40kHz then somewhat less sensitive at 60kHz then be very sensitive again around 80kHz Micro after a certain frequency When w this is the point where the frequency response has begun to taper off However the mic...

Page 11: ...ype of batteries being used as well as ambient temperature length of your recording session and amount of bat activity ambient noise if using triggered ultrasonic recording Four high quality alkaline AA batteries last up to 300 hours of acoustic recording or up to 40 nights of triggered ultrasonic recording based on 10 bat activity at 25o C and 10 hour nights However in practice recording conditio...

Page 12: ...Acoustic 48Ksps 330MB 660MB Acoustic 44 1Ksps 303MB 606MB Acoustic 32Ksps 220MB 440MB Acoustic 22 05Ksps 152MB 303MB Please note In all modes except Schedule mode when there is an SD card present the Chorus will periodically display the remaining recording time for your SD card in the top left of the display based on the currently chosen sample rate A note on triggered ultrasonic recording During ...

Page 13: ...nd you check for firmware updates see UPDATE FIRMWARE STEP BY STEP GUIDE 1 Connect your chosen microphone s to the appropriate side see below acoustic can be on side A latch or B hinge ultrasonic on side B hinge only refer to the image below Carefully insert the microphone jack into the microphone socket with locking tabs in correct alignment until it clicks into place Rotate the microphone clockw...

Page 14: ...cked and correctly orientated as per the diagram on the control panel when inserting Refer to the Data Storage Requirements and Power Requirements above for more information on what size SD card and batteries to use Align jack and locking tabs Turn 1 8th turn to stop B A Ultrasonic mic Acoustic mic Acoustic mic only OR ...

Page 15: ...S fix is obtained the GPS icon on the screen will stop flashing The GPS fix will automatically set the clock record the GPS location and determine the sunset sunrise times 7 If an issue requires your attention the corresponding status icon will be flashing as well as the Check LED on the outside of the unit Check the Dashboard status messages for more information regarding the issue see Flashing S...

Page 16: ...Sleep mode and press the K button again In sleep mode the screen will be off but the device will still record To turn the screen back on briefly press the K button again The Chorus will also automatically enter sleep mode to save power if there has been no user interaction for one minute Power off Sleep UPDATING FIRMWARE It is important to keep the firmware on the Chorus up to date to ensure troub...

Page 17: ...indicate which mode is selected if no LEDs are lit the recorder is in Inactive Mode and will not record Inactive mode is useful while configuring your recorder to avoid creating unwanted recordings Most modes require a GPS fix on the deployment day as the recorder automatically calculates the sunset and sunrise times based on the current longitude and latitude If the recorder is left on it will co...

Page 18: ...ule created with the Scheduler Tool in Anabat Insight see CREATING SCHEDULES You can create schedules based on sunset sunrise times or on absolute times You can create multiple tasks to activate different microphones and sample rates at different times The schedule is saved on the SD Card so keep this in mind when swapping out the SD card Schedule mode requires a GPS fix if your schedule is based ...

Page 19: ...onic Microphone Different recording options will be available depending on whether you select an ultrasonic or acoustic sample rate To change the sample rate ensure Sample Rate is selected in the Recording Settings menu then use the left right arrow buttons to change the sample rate Notes on sample rate and file type The chosen sample rate should be at least double the highest frequency sound of i...

Page 20: ...tude of the recorded microphone signal You can adjust the gain of each of the two acoustic microphones independently in increments of 3dB up to 15dB Use the up down arrow buttons to select Gain and then use the left right arrow buttons to choose the gain that you want a higher dB represents an increased amplitude A higher gain setting will pick up more sounds but the recording will become distorte...

Page 21: ...ode selected Night Only Dusk Dawn Day Only Continuous or Schedule The trigger is dependent on the trigger settings such as Sensitivity and Minimum Frequency amongst others Triggered activation mode is most often used for ultrasonic bat recording The constant activation mode will record all sound constantly without triggers in whichever recording mode is selected Night Only Dusk Dawn Day Only Conti...

Page 22: ...e Max Freq then use the left right arrow buttons to change the frequency The default value is 250 kHz It is generally not necessary to adjust this setting unless you would like to exclude triggering on higher frequencies Minimum Event This is the minimum duration sound that will trigger a recording You can set this to the minimum duration sound e g bat pulse to be recorded To change this use the u...

Page 23: ... have the filter On unless intending to record sounds under 10KHz To change this use the up down arrow buttons to select the 10k HP Filter then use the left right arrow buttons to choose between On and X Off Division Ratio ZC File Type Only The division ratio affects the amount of data which is saved in Zero Crossing recordings the lower the division ratio the greater the number of data points in ...

Page 24: ...on on the dashboard see below then press the K button to select TRANSECT MODE Transect mode will use the built in GPS to save your track as a GPX file by logging GPS points once per second To turn on transect mode use the up down arrow buttons to select Transect Mode then use the left right arrow buttons to choose between On and X Off Note that using transect mode will approximately halve the batt...

Page 25: ...ocation Altitude When the last GPS fix was received The number of satellites currently in use typically more satellites indicates a more accurate fix HDOP horizontal dilution of precision The lower the number the more accurate the position Numbers less than one typically indicate good accuracy Whether the fix is 2D inaccurate or 3D more accurate Whether the GPS is currently on GPS will automatical...

Page 26: ...ULE To check or change the time zone setting on your detector use the left right arrows to navigate to the Clock Settings see below and press the K button use the up down arrows to navigate the Clock Settings menu Time Zone Your time zone relative to Greenwich Mean Time GMT will be shown Use the left right arrows to change the time zone in 15 minute increments Remember to account for any daylight ...

Page 27: ... down arrow to navigate to the bottom of the settings menu Reset to defaults Once selected press the K button to reset all settings in this particular menu to the factory defaults RECORDER STATUS INFO To see the recorder status and other information press the right soft key on the dashboard This will display Recorder serial number Firmware version Bootloader version Main battery AA voltage around ...

Page 28: ...ingers in front of the microphone you should be able to hear the ultrasonic audio signal in frequency division in both ears When checking acoustic microphone s you will hear an audio reproduction in the left and or right ears either mono or stereo depending on the number of acoustic microphones The amplitude of the acoustic audio will depend on the gain chosen in the microphone settings 3 To test ...

Page 29: ...full eject the SD card and replace it Card Locked The SD card is locked remove the card and unlock the write protection switch lock before reinserting Bad SD Card If the card is corrupt or cannot be read Either replace the card or attempt to reformat the card Remove SD Card W this message will disappear once you have removed the SD card Cannot Eject Now The card cannot be ejected wait a moment and...

Page 30: ...r side whereas the ultrasonic microphone must be connected to side B Ensure you have the ultrasonic microphone connected when using ultrasonic recording accidentally leave an acoustic microphone connected on side B or vice versa Your recording settings must match your installed microphone configuration Make sure your chosen sample rate and microphone are correct Clock Time Zone Not Set Time zone i...

Page 31: ...low 4 5V replace the batteries before starting recording Clock Battery Low The CR2032 Coin Cell battery has dropped below 2 6V replace the clock battery Leave AA batteries installed while changing the clock battery to avoid loss of your settings ...

Page 32: ...nt reducing its sensitivity 3 If recording is required during rain the microphone should be mounted in such a way so that water cannot land on the microphone element 4 Dry off the case and microphone before opening the recorder or removing the microphones This prevents moisture from entering the recorder 5 The recorder should not be partially or fully submerged in water 6 Desiccant sachets can be ...

Page 33: ...s off the microphone s and doesn t settle on the element s Also make sure that the magnetic lanyard or the device itself is not being blown around in the wind as this may create unwanted noise on your recordings It is also important to avoid surface noise such as vegetation brushing against the recorder case or microphone You can also purchase a gooseneck microphone extender which we recommend for...

Page 34: ...nside of the case is completely dry before closing the lid To turn the recorder off open the case press the K button to bring up the Sleep Off menu continue holding the button until the unit shuts down or release then then press the K button again to shut down immediately If the recorder does not respond to the power button the batteries may have gone flat Remove the SD card to download the data t...

Page 35: ...the log file with the recording files Files will be arranged on the card in folders as follows Acoustic This folder contains the acoustic sound recordings Ultrasonic This folder contains the ultrasound recordings Log This folder contains the log files for the deployment This should be kept in case and future troubleshooting is required GPS This folder contains the transect GPX files FILE NAMES Log...

Page 36: ...splay metrics for passes and individual bat pulses View customize metadata Generate reports to present your analysis results Use built in mapping to view your tracks waypoints Export mapping data to GIS programs Listen to and view spectrograms of stereo and mono acoustic recordings Create custom recording schedules to be used on the Chorus CREATING SCHEDULES In Anabat Insight you can create a cust...

Page 37: ...he recording If you want to have multiple periods per day these should created as separate tasks You can choose when to start end relative to sunset sunrise an absolute time as well as end relative to start time e g end 3 hours after start time d Duty Cycle If you wish recording to start and stop for fixed periods within your schedule e g record 5 mins on then 5 mins off By default a schedule will...

Page 38: ...hedule ensure you have connected the appropriate microphone s to the correct sides of the Chorus b Choose the settings appropriate to your microphone and survey goals Task Settings Sample Rate The sample rate the recorder will use for this task Gain A Set the gain for the acoustic microphone on Side A Gain B Set the gain for the acoustic microphone on Side B Activation Choose between Constant or T...

Page 39: ...rgence Please note Not all Task settings listed above will be available it will depend on your Microphone and Activation For more information on each setting click the setting name 7 Ensure all schedule tasks you would like enabled are checked in the Schedule Manager see below 8 Once you have finished creating your schedule task you can either add another task repeat steps 2 5 or you can save the ...

Page 40: ... onto multiple SD cards to use on Example schedules are shown on the following pages Example 1 The above schedule will record daily from 8 22 October from 1hr before sunset to 2hrs after sunset in ultrasonic full spectrum default settings Every file recorded will include the metadata Bat Survey Dusk ...

Page 41: ...Every file recorded will include the metadata Bird Survey Dawn Example 3 The above schedule will record Monday Wednesday Friday and Sunday nights from 8 October for 1 month from 2hrs after sunset to 90 mins before sunrise in ultrasonic zero crossing sensitivity 17 minimum frequency 17 Every file recorded will include the metadata Bat Survey Night Activity ...

Page 42: ...schedule 1 Insert the SD card with the schedule csv saved on it 2 Turn the detector on using the K button then use the arrows to select the Clock Settings and press the K button again 3 Use the down arrow to select Schedule then press the K button 4 Your schedule tasks will be listed by name to view a task use the up down arrows to navigate to it then press the K button 5 It will display the date ...

Page 43: ...ettings Battery voltage Custom metadata if using a schedule TROUBLESHOOTING FAQS How do I set up the detector for ultrasonic bat recording If you are using the Chorus with an ultrasonic microphone to record ultrasonic frequencies e g bat echolocation you will need to check the following settings 1 Mount an ultras side B 2 Place the recorder in your desired Recording Mode e g Night Only Continuous ...

Page 44: ...loyment Do not deploy until you resolve the issue To check the issue s open the case and look at the status message s on the dashboard See Flashing Status Icons for more information on how to resolve these issues Can I record ultrasonic and acoustic at the same time You are unable to record ultrasonic and acoustic simultaneously however you can create a schedule to record ultrasonic and acoustic d...

Page 45: ...pable of recording stereo acoustic files Dual Dual recording is recording multiple files from two microphones on a schedule but not simulta 2pm This is possible using a custom schedule with the Chorus Simultaneous Simultaneous recording is the ability to record multiple files from two or This is not possible with the Chorus There are a lot of echoes in the spectrogram When recording in full spectr...

Page 46: ...recording analysis The advantage of zero crossing analysis is the small file size so memory space is not an issue and many published guides to bat calls are based on zero crossing analysis The disadvantages of zero crossing are that spectral information is lost which may be helpful to species identification and that in cases of high frequency ambient noise e g insects bat calls may not be recorded...

Page 47: ...ry conditions will allow the detection of bat calls over greater distances The sensitivity of the recorder also has a major influence on detection distance and while there is always some variability in sensitivity among units the biggest influence is the sensitivity setting Given all the above it is obvious that detection distances will vary enormously Many bats are easily detected over 30m under ...

Page 48: ...ower the recorder using solar panels or external battery No the Chorus cannot be powered externally FURTHER INFORMATION For further information please visit the Titley Scientific website www titley scientific com ...

Reviews: