TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com

READ OWNERS INSTRUCTIONS CARE-

FULLY PRIOR TO INSTALLATION.

THESE INSTRUCTIONS MUST REMAIN

WITH EQUIPMENT. DO NOT DESTROY.

AIRESHARE

TM

ROOM-TO-ROOM TRANSFER FAN 

MODEL AS2

©2014        TJERNLUND PRODUCTS, INC.  ALL RIGHTS RESERVED

P/N: 8504213  

DESCRIPTION

The Tjernlund AireShare™ Room-to-Room Transfer fans distribute air from one conditioned space to another. Virtually every home has
a room that is uncomfortably hot or cold from which some of that room’s air can be shared with an adjacent room, making the tempera-
ture of both rooms more comfortable. The AireShare™ transfers air through the wall cavity created between two wall studs. The
AireShare’s unique option of moving the air up or down within the wall cavity allows for optimum heat transfer between rooms. In addi-
tion, locating the Grille and Diffuser, one high the other low, prevents the transfer of light and sound between these adjacent rooms.

AS2 SPECIFICATIONS & COMPONENTS

GENERAL INFORMATION

Every Tjernlund AireShare™ Room-to-Room Transfer fan is electrically factory line tested before shipment.

After opening carton, inspect thoroughly for shipping damage. Impeller should rotate freely and all electrical wires and connections
should be secured. If any damage is found, notify freight carrier and your distributor immediately and file a concealed damage claim.

SPEED SELECTION ADVICE

Since it is impractical to calculate heating and cooling loads for the variety of geographic areas, construction methods and the tempera-
ture of transferred air we base our model selection advice on providing a minimum of 3 Air Changes/Hour (ACH) to the target room.
Door under-cuts or pressure relief transfer grilles in the target room are necessary for proper AireShare performance.

(AireShare CFM x 60) / (L x W x H of target room) = ACH    

NOTE:

Aireshare CFM is 110 on High, 95 on Med and 80 on Low

3-4 Air Changes/hour (ACH) recommended for best temperature equalization.

4-5 Air Changes/hour (ACH) recommended for rooms with high cooling or heating loads.  Examples include rooms with extensive out-
side walls, windows, over tuck under garages or in extreme climates. More than one AireShare transfer fan can be installed to reach
desired number of air changes for large spaces.

INSTALLATION RESTRICTIONS 

The AireShare™ Transfer fan must be installed by a qualified installer in accordance with these instructions and all local codes, includ-
ing fire-rated construction. In their absence, install in accordance with the latest editions of the International Residential Code and
International Electrical Code. Improper installation can create a hazardous condition such as fire, electric shock or personal injury. To
reduce these risks significantly, use this device only in the manner intended by the manufacturer. If you have questions about proper
usage of this device, call Tjernlund.

Always disconnect the AireShare™ Transfer fan from its power source before installation and servicing.

IMPORTANT:

An in depth investigation of the wall layout is required prior to installation. Avoid a stud wall section that is a path for

plumbing supply lines, drains and vents. Avoid a stud wall section that is insulated or being used as a return air duct for a forced air 
system. If stud walls are constructed with metal studs, order Tjernlund Model DK2 Duct Kit or seal all metal stud openings.

Blower:

3 Speed: 110 CFM, 95 CFM, 80 CFM (Wire for desired speed upon install or use optional AS2SW3 3-speed switch kit.) 

Motor:  

120 Volts ~ 60 Hz ~ Thermal Switch Protected (Moter Protection Thermique)
0.50 amps maximum, Watts (30 High, 21 Med,16 Low)

Impeller:

Dual Inlet, Low RPM

Dimensions: Diffuser:

3” x 15 1/8” (flush)     

Diffuser Rough Opening:  1 1/4” High x 13 5/8” Wide

Blower Grille:

16” x 10” x 2 1/2”

Blower Rough Opening:

7 1/4” High x 14 1/2” Wide

Color:

Neutral White 

Summary of Contents for AIRESHARE AS2

Page 1: ...roper AireShare performance AireShare CFM x 60 L x W x H of target room ACH NOTE Aireshare CFM is 110 on High 95 on Med and 80 on Low 3 4 Air Changes hour ACH recommended for best temperature equalization 4 5 Air Changes hour ACH recommended for rooms with high cooling or heating loads Examples include rooms with extensive out side walls windows over tuck under garages or in extreme climates More ...

Page 2: ...y open See Diagram B TOOLS REQUIRED Hand Sheetrock Saw Phillips Straight Screwdrivers Level Tape Measure Utility Knife or Scissors Wire Stripper INSTALLING DISCHARGE DIFFUSER WARNING Disrupt power at circuit breaker to outlets and switches within the stud wall you will be working When sawing through sheetrock you must stop if you detect the saw blade coming in contact with any wiring or plumbing I...

Page 3: ...mark the grille position through the two mounting holes IMPORTANT Make sure Intake Grille flanges do not interfere with baseboards outlets If Intake Grille is mounted up high towards the ceiling the top flange must be mounted 1 below the ceiling so Intake Grille top opening clears double plate at top of stud walls See Diagram H 3 Mark a level line 3 5 8 straight above and below each Intake Grille ...

Page 4: ...ired to the brown motor lead If wiring into a switched 120 VAC power source follow the AS2 connection diagram below If using the optional FC24 Fan Center to control the Aireshare by a 24 volt thermostat follow the FC24 wiring diagrams CAP 2 5 uF CAP 6 uF CAP 5 uF 8089034 10 27 14 MOTOR AS2 BLOWER AS2 ELECTRICAL BOX CABLE L1 60 Hz 120 VAC N GROUND BLK GRN WIRE NUTS BY OTHERS SUPPLIED BLK BRN GRN YE...

Page 5: ... G R N Y E L B R N T STAT WIRING SEE FC24 B L K BLK GRN WIRE NUTS BY OTHERS SUPPLIED L1 HIGH SPEED AS2 BLACK LEAD CAP 6 uF CAP 5 uF L1 MED SPEED L1 LOW SPEED AS2 BLACK LEAD AS2 BLACK LEAD A 2 5 uF CAPACITOR IS ALWAYS USED ON THE 120 VAC N LEAD AND IS WIRED BETWEEN THE WHITE AND BROWN LEADS OF THE MOTOR NOTE OR OR AS2 SPEED OPTIONS BELOW AIRESHARETM MODEL AS2 WIRING CONNECTIONS WITH THE OPTIONAL FC...

Page 6: ...A 120 24 YEL VIO GRY BLK 8089031 9 4 14 FC24 7 8 3 6 R WALL THERMOSTAT NO C TERMINAL 24 VAC WIRE LEGEND 24 VAC 120 VAC BY OTHERS RED YEL BLK WHT XFORMER 20 VA 120 24 YEL VIO GRY BLK FC24 7 8 3 6 G W Y R WALL THERMOSTAT WITH C TERMINAL 24 VAC C WIRE LEGEND 24 VAC 120 VAC BY OTHERS FC24 T STAT WIRING G W Y 120 VAC WIRING AS1 AS2 SEE 120 VAC WIRING AS1 AS2 SEE FAN ON HEAT COOL G W Y FAN RUNS CONSTANT...

Reviews: