TJERNLUND LIMITED ONE YEAR WARRANTY
Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1)
year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our
option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE
NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WAR-
RANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED
WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts,
so that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or
exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from State to State. Send all inquiries
regarding warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 •
Email fanmail@tjfans.com.
RED
YEL
BLK
WHT
XFORMER
20 VA
120 / 24
YEL
VIO
GRY
BLK
8089031 9/4/14
FC24
7
8
3
6
R
WALL THERMOSTAT
NO "C" TERMINAL
24 VAC
WIRE LEGEND
24 VAC
120 VAC
BY OTHERS
RED
YEL
BLK
WHT
XFORMER
20 VA
120 / 24
YEL
VIO
GRY
BLK
FC24
7
8
3
6
G / W / Y
R
WALL THERMOSTAT
WITH "C" TERMINAL
24 VAC
C
WIRE LEGEND
24 VAC
120 VAC
BY OTHERS
FC24 T-STAT WIRING
*
G / W / Y
*
120 VAC
WIRING
AS1 / AS2
SEE
120 VAC
WIRING
AS1 / AS2
SEE
(FAN ON)
(HEAT)
(COOL)
G
W
Y
= FAN RUNS CONSTANTLY.
= FAN RUNS ON TEMPERATURE FALL.
= FAN RUNS ON TEMPERATURE RISE.
*
OPTIONAL FC24 FAN CENTER T-STAT WIRING CONNECTIONS
24 VAC WALL T-STAT WITH NO “C” TERMINAL
24 VAC WALL T-STAT WITH “C” TERMINAL
MAINTENANCE & SERVICE
The AireShare™ Blower wheel should be inspected annually and carefully cleaned or vacuumed with a bristle brush head if necessary.
The motor is permanently lubricated and requires no maintenance.
IMPORTANT:
Before servicing or cleaning this unit, unplug the unit or switch power off at the service panel and lock the service discon-
necting means to prevent power from being switched on accidentally. When the service disconnecting means can not be locked,
securely fasten a prominent warning device, such as a tag, to the service panel.
ACCESSORY CONTROLS
AS2SW3 3-Speed Switch kit for High, Med & Low control at wall
FC24
24V Fan Center to interface any 24V Thermostat (Allows control on temperature rise & fall with 24V thermostat)
SWT Switch-It
TM
Wireless Digital Thermostat (Heat Only Applications - Activates on temperature fall)
SWS Switch-It
TM
Wireless Wall Switch
DK2
AS2 Duct Kit for installation in obstructed wall cavities, where metal studs with
wiring knock outs are used or to conform to energy codes requiring metal ducts.
REPLACEMENT PARTS AND WARRANTY
Component
Part Number
Component
Part Number
AS2 Intake Grille
950-3320
AS2 Blower Assembly
950-3319
AS1, AS2 Diffuser
950-3302
AS2 Motor Capacitor Kit
950-3321