background image

TJERNLUND LIMITED ONE YEAR WARRANTY

Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1)
year from the date of original purchase or delivery to the original purchaser, whichever is earlier.  Remedies under this warranty are limited to repairing or replacing, at our
option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid.  THERE ARE
NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT.  THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WAR-
RANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY.  IMPLIED
WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY.  Some states do not allow limitation on how long an implied warranty lasts,
so that limitation may not apply to you.  In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or
exclusion may not apply to you.  This warranty gives you specific legal rights and you may also have other rights which may vary from State to State.  Send all inquiries
regarding warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794.  Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 •
Email fanmail@tjfans.com.

RED

YEL

BLK

WHT

XFORMER

20 VA

120 / 24

YEL

VIO

GRY

BLK

8089031     9/4/14

FC24

7

8

3

6

R

WALL THERMOSTAT

NO "C" TERMINAL

24 VAC

WIRE LEGEND

24 VAC

120 VAC

BY OTHERS

RED

YEL

BLK

WHT

XFORMER

20 VA

120 / 24

YEL

VIO

GRY

BLK

FC24

7

8

3

6

G / W / Y

R

WALL THERMOSTAT

WITH "C" TERMINAL

24 VAC

C

WIRE LEGEND

24 VAC

120 VAC

BY OTHERS

FC24 T-STAT WIRING

*

G / W / Y

*

120 VAC

WIRING

AS1 / AS2

SEE

120 VAC

WIRING

AS1 / AS2

SEE

(FAN ON)
(HEAT)
(COOL)

G

W

 Y

= FAN RUNS CONSTANTLY.
= FAN RUNS ON TEMPERATURE FALL.
= FAN RUNS ON TEMPERATURE RISE.

*

OPTIONAL FC24 FAN CENTER T-STAT WIRING CONNECTIONS

24 VAC WALL T-STAT WITH NO “C” TERMINAL

24 VAC WALL T-STAT WITH “C” TERMINAL

MAINTENANCE & SERVICE

The AireShare™ Blower wheel should be inspected annually and carefully cleaned or vacuumed with a bristle brush head if necessary.
The motor is permanently lubricated and requires no maintenance.

IMPORTANT: 

Before servicing or cleaning this unit, unplug the unit or switch power off at the service panel and lock the service discon-

necting means to prevent power from being switched on accidentally. When the service disconnecting means can not be locked,
securely fasten a prominent warning device, such as a tag, to the service panel. 

ACCESSORY CONTROLS

AS2SW3   3-Speed Switch kit for High, Med & Low control at wall

FC24 

24V Fan Center to interface any 24V Thermostat (Allows control on temperature rise & fall with 24V thermostat)

SWT Switch-It

TM

Wireless Digital Thermostat (Heat Only Applications - Activates on temperature fall)

SWS Switch-It

TM

Wireless Wall Switch

DK2

AS2 Duct Kit for installation in obstructed wall cavities, where metal studs with 
wiring knock outs are used or to conform to energy codes requiring metal ducts.

REPLACEMENT PARTS AND WARRANTY

Component

Part Number

Component

Part Number

AS2 Intake Grille 

950-3320

AS2 Blower Assembly

950-3319

AS1, AS2 Diffuser

950-3302

AS2 Motor Capacitor Kit

950-3321

Summary of Contents for AIRESHARE AS2

Page 1: ...roper AireShare performance AireShare CFM x 60 L x W x H of target room ACH NOTE Aireshare CFM is 110 on High 95 on Med and 80 on Low 3 4 Air Changes hour ACH recommended for best temperature equalization 4 5 Air Changes hour ACH recommended for rooms with high cooling or heating loads Examples include rooms with extensive out side walls windows over tuck under garages or in extreme climates More ...

Page 2: ...y open See Diagram B TOOLS REQUIRED Hand Sheetrock Saw Phillips Straight Screwdrivers Level Tape Measure Utility Knife or Scissors Wire Stripper INSTALLING DISCHARGE DIFFUSER WARNING Disrupt power at circuit breaker to outlets and switches within the stud wall you will be working When sawing through sheetrock you must stop if you detect the saw blade coming in contact with any wiring or plumbing I...

Page 3: ...mark the grille position through the two mounting holes IMPORTANT Make sure Intake Grille flanges do not interfere with baseboards outlets If Intake Grille is mounted up high towards the ceiling the top flange must be mounted 1 below the ceiling so Intake Grille top opening clears double plate at top of stud walls See Diagram H 3 Mark a level line 3 5 8 straight above and below each Intake Grille ...

Page 4: ...ired to the brown motor lead If wiring into a switched 120 VAC power source follow the AS2 connection diagram below If using the optional FC24 Fan Center to control the Aireshare by a 24 volt thermostat follow the FC24 wiring diagrams CAP 2 5 uF CAP 6 uF CAP 5 uF 8089034 10 27 14 MOTOR AS2 BLOWER AS2 ELECTRICAL BOX CABLE L1 60 Hz 120 VAC N GROUND BLK GRN WIRE NUTS BY OTHERS SUPPLIED BLK BRN GRN YE...

Page 5: ... G R N Y E L B R N T STAT WIRING SEE FC24 B L K BLK GRN WIRE NUTS BY OTHERS SUPPLIED L1 HIGH SPEED AS2 BLACK LEAD CAP 6 uF CAP 5 uF L1 MED SPEED L1 LOW SPEED AS2 BLACK LEAD AS2 BLACK LEAD A 2 5 uF CAPACITOR IS ALWAYS USED ON THE 120 VAC N LEAD AND IS WIRED BETWEEN THE WHITE AND BROWN LEADS OF THE MOTOR NOTE OR OR AS2 SPEED OPTIONS BELOW AIRESHARETM MODEL AS2 WIRING CONNECTIONS WITH THE OPTIONAL FC...

Page 6: ...A 120 24 YEL VIO GRY BLK 8089031 9 4 14 FC24 7 8 3 6 R WALL THERMOSTAT NO C TERMINAL 24 VAC WIRE LEGEND 24 VAC 120 VAC BY OTHERS RED YEL BLK WHT XFORMER 20 VA 120 24 YEL VIO GRY BLK FC24 7 8 3 6 G W Y R WALL THERMOSTAT WITH C TERMINAL 24 VAC C WIRE LEGEND 24 VAC 120 VAC BY OTHERS FC24 T STAT WIRING G W Y 120 VAC WIRING AS1 AS2 SEE 120 VAC WIRING AS1 AS2 SEE FAN ON HEAT COOL G W Y FAN RUNS CONSTANT...