Performance 

Air flow (0 Bar / 0 PSI) 

86 LPM / 3.0 CFM 

Air Flow (200 kPa / 29 PSI) 

66 LPM / 2.3 CFM 

Duty Cycle (80 PSI, 60 minutes @ 23°C) 

100 % 

Pressure Switch Operation 

Off @ 120 PSI / On @ 90 PSI 

Safety Relief Valve Opening Pressure 

1070 kPa / 155 PSI 

1.4

 

Hardware and Fittings 

Pro Locker Solenoid / Pressure Switch ports 

6 x 

⅛” 

BSPT ports (3 each side of air tank) 

Tyre Inflation / Accessory ports 

2 x ¼” 

BSPT ports (1 each side of air tank) 

Safety Relief Valve 

Factory-set 155 PSI, 

⅛” NPT male thread

 

Compressor to Bracket Bolts (Included) 

6 x M5 x 15 Socket-head Cap screw 

Base-plate to Vehicle Bolts (Not Included) 

4 x M6 or M8 bolts and nuts 

1.5

 

Recommended Fastener Torque Settings 

M5 

9.5 Nm 

M6 

16 Nm 

⅛” 

BSPT 

15 Nm 

¼” 

BSPT 

20 Nm 

2.0

 

Compressor Assembly  

2.1

 

Accessory Installation 

Installation Conditions: 

The 12 V solenoid shown is supplied with the TJM Pro Locker.  

The ¼” 

BSPT hose fitting shown is supplied with the TJM Airline Kit 

 

3 x 

⅛” and 1 x ¼” ports shown.

 

Additional ports on opposite side of air tank. 

o

 

Determine the desired mounting 
configuration for the compressor and select 
the desired outlet ports for the accessories 

 

there are 8 available outlet ports in total. 
 

o

 

To fit the Pressure Switch and Pro-Locker 
solenoids, remove one of the 

⅛”

 BSPT plugs in 

the air tank using a 5mm hex key. 
 

o

 

To fit the TJM Airline Kit, remove one of the 

¼” 

BSPT plugs in the air tank using a 6 mm 

hex key. 

If necessary, remove the safety relief valve to 

provide space for the accessory fitment. 

Summary of Contents for 013COMPVHD

Page 1: ...nd is used in accordance with accompanying instructions where provided For product warranty please refer to our website www tjm com au Estimated Fitting Time 2 hrs Treat any holes drilled into the veh...

Page 2: ...Post Installation Examination 9 6 0 Operating Instructions 9 7 0 Maintenance 11 1 0 Compressor Specifications 1 1 Bill of Material Item No QTY Part Number Description 1 1 F 17615 Compressor 2 1 013COM...

Page 3: ...screw Base plate to Vehicle Bolts Not Included 4 x M6 or M8 bolts and nuts 1 5 Recommended Fastener Torque Settings M5 9 5 Nm M6 16 Nm BSPT 15 Nm BSPT 20 Nm 2 0 Compressor Assembly 2 1 Accessory Insta...

Page 4: ...f the safety relief valve was removed apply sealant paste or sealant tape and re install the valve to the same port Notes DO NOT over tighten may cause damage to thread If using a thread sealant allow...

Page 5: ...placed Contact a TJM Distributor for service 3 0 Vehicle Mounting 3 1 Mounting Location When deciding an appropriate place to mount the compressor within the vehicle consider the following o Avoid pro...

Page 6: ...hers are fitted between the screw and rubber isolator o It is possible to undo the screws on one side of the compressor and rotate the body of the compressor to give better access to the base plate o...

Page 7: ...iring System Installation Conditions Installation following this diagram requires the Rear Locker to be active to select the Front Locker This prevents unexpected handling changes from accidental Fron...

Page 8: ...ont Locker Solenoid o Plug the compressor motor connector into the Red White and Black loom connector o Fit ring terminals the ends of the Red and Black 10 AWG wires o Connect the red wire to the batt...

Page 9: ...bles will appear at the source of the leak o De pressurise the system o Re tighten the leaking fitting s and repeat leak test o If leaking continues remove fittings reapply sealant and then re assembl...

Page 10: ...alled o Never blow compressed air directly at people or pets Compressed air can blow dirt particles into the atmosphere which can irritate the skin eyes and or respiratory system o Do not use the comp...

Page 11: ...ife of the compressor o Periodically check fittings and airlines for leaks o Periodically inspect mount bolts to ensure that they remain tight o Periodically check the safety relief valve ensure air i...

Page 12: ...blade fuse Relay blown Test with another relay and replace if required Faulty pressure switch Check for voltage at relay terminal 86 Replace switch if required Compressor switches on and off frequent...