6.
Operating Instructions
Pro Locker activation
o
Switch on the compressor from the actuator switch.
o
The compressor will pressurise to approximately 120 PSI and then automatically switch off.
o
Use the Pro Locker actuation switches to engage and disengage the Lockers as needed.
o
When system pressure drops below 90 PSI the compressor will automatically switch on.
o
After use switch off both the Locker switches and the compressor switch.
Tyre inflation
o
Connect the
hose for tyre inflation to the compressor using the ¼”
BSPT port with a quick-connect
fitting (supplied in TJM Airline Kit).
o
Switch on the compressor from the actuator switch.
o
The compressor will pressurize to 120 PSI and then automatically switch off.
o
Connect the tyre chuck to the tyre valve to inflate. The compressor with automatically restart to supply
air once the tyre is connected.
o
Check desired pressure is reached using a tyre pressure gauge. Note: measure the pressure with no
air-flow to the tyre for accurate reading.
o
After use switch off the compressor.
Safety information
o
The compressor will become
very hot
during use. Do not touch the working end of the compressor
during or immediately after use. Wear gloves when changing the hose connection.
o
Always ensure air pressure in the compressor is discharged before installing hoses and fittings or
undertaking maintenance.
o
Do not operate the unit without the safety relief valve installed.
o
Never blow compressed air directly at people or pets. Compressed air can blow dirt particles into the
atmosphere which can irritate the skin, eyes and/or respiratory system.
o
Do not use the compressor without mounting to a solid surface.