24
Figure T-
568B
7.2
Connecting card reader
7.2.1
RS485 card reader
Choosing the option to connect RS485 card readers to the controller offers the following
advantages:
•
‘Key information’ from the card reader is transferred to the controller. The card reader
is always publicly accessible, while the controller is located in a secure and concealed
area. This means that the settings required for reading cards are located in the controller
instead of in the card reader.
•
Communication between cards and the system can be secured by means of AES
encryption.
•
When (the maximum of) four Orions are connected to a Pluto (see figure 13), a maximum
of eight RS485 card readers can be connected.
7.2.1.1
Connection of RS485 card reader
PRT1(A)- 2(L)
Sirius i-serie
Nr. Description
Wire color
Sticker
Description
1
B
White/Orange
2
B
2
A
Orange
1
A
3
B (Z)
White/Green
2
B
4
12Vdc
Blue
Vcc
Vcc
5
GND
White/Blue
GND
GND
6
A (Y)
Green
1
A
7
GND
White/Brown
GND
GND
8
GND
Brown
GND
GND
Polyx
1 2 3
RS485
N D
Front
Rear
RS485
N
PRT2
Orion Pluto
USB
PRT1
RS485
L
A
Max. 4x Orion
Max. 4x Orion
Figure 15: Polyx with
RS485 card reader
Figure 16: Pluto with
RS485 card reader
X
Summary of Contents for KEYPROCESSOR Orion
Page 1: ...1 Pluto Orion Doc no 01052018 Modular controller line Installation instructions ...
Page 4: ...4 ...
Page 58: ...58 14 2 72000206 Pluto Orion with Sirius RS485 and IO ...
Page 59: ...59 14 3 72000202 Pluto Orion with Sirius clock data Wiegand and I O ...
Page 60: ...60 14 4 72000207 Pluto Orion with IO Sirius Clock data Wiegand and Orbits ...
Page 61: ...61 14 5 72000304 Pluto with power supply and USB RS232 converter ...
Page 62: ...62 14 6 72000203 Pluto Orion with kpBus ...
Page 63: ...63 14 7 72000204 Orion with kpSensor bus ...
Page 64: ...64 14 8 72000602 Pluto Orion stacked with 8x RS485 Sirius i readers ...
Page 65: ...65 14 9 72000602 Pluto Orion with clock data or Wiegand readers ...
Page 66: ...66 14 10 72000602 Pluto Orion with RS485 readers kpBus combi ...