Pluto-Orion as replacement for the iPU-8
A Pluto in combination with the Orion can serve as a functional replacement unit for the Stellar
or ipU-8 Network Controller.
When an existing iPU-8 with 8 Orbits installation needs to be replaced, a Pluto with 4 stacked
Orions will suffice. Each Orion can be linked with maximal two Orbits. The type of Orbit is in this
case not relevant (Orbit-1, Orbit-2 or Obit-IO).
NOTE
The existing UTP cabling of the Orbit is connected to the S2M cable. This must be
connected to the Orion. The cable length between iPU-8 and Orbit or between
Orion and Orbit remains unchanged.
In the picture below there is an example of replacing an iPU-8 for a Pluto and Orion:
Clock- Data /
Wiegand
iPU-8
N
1 2 3 4 5 6 7 8
Orbit-1
Orbit-2
Max 8
S2M cable to PRT1
Orbit-2
Front side
PRT2
Orion Pluto
N
S2M cable to PRT2
Orbit-1
Clock- Data /
Wiegand
Clock- Data /
Wiegand
Figuur 28: iPU-8 with 2 Orbits
Figure 27: Pluto and Orion with 2 Orbits
X
Summary of Contents for KEYPROCESSOR Orion
Page 1: ...1 Pluto Orion Doc no 01052018 Modular controller line Installation instructions ...
Page 4: ...4 ...
Page 58: ...58 14 2 72000206 Pluto Orion with Sirius RS485 and IO ...
Page 59: ...59 14 3 72000202 Pluto Orion with Sirius clock data Wiegand and I O ...
Page 60: ...60 14 4 72000207 Pluto Orion with IO Sirius Clock data Wiegand and Orbits ...
Page 61: ...61 14 5 72000304 Pluto with power supply and USB RS232 converter ...
Page 62: ...62 14 6 72000203 Pluto Orion with kpBus ...
Page 63: ...63 14 7 72000204 Orion with kpSensor bus ...
Page 64: ...64 14 8 72000602 Pluto Orion stacked with 8x RS485 Sirius i readers ...
Page 65: ...65 14 9 72000602 Pluto Orion with clock data or Wiegand readers ...
Page 66: ...66 14 10 72000602 Pluto Orion with RS485 readers kpBus combi ...