background image

 

172-65236MA-04  (DC3-L)      7  Oct  2021

 

4

 

Specifications 

 

 

Install properly and DO NOT use this product outside the recommended 

operating pressure, temperature and other specification ranges. 

Improper use may result in such hazards as damage to the product or 

malfunctions which may lead to serious accidents. Local regulations 

may restrict the use of this product to below the conditions quoted.

 

CAUTION 

 

 

Use only under conditions in which no freeze-up will occur. Freezing 

may damage the product, leading to fluid discharge, which may cause 

burns or other injury.

 

CAUTION 

Refer to the product nameplate for detailed specifications.   

 

*Maximum allowable pressure (PMA) and maximum allowable temperature (TMA) are 

PRESSURE SHELL DESIGN CONDITIONS, 

NOT

 OPERATING CONDITIONS. 

**Valve No. is displayed for products with options. This item is omitted from the nameplate 

when there are no options. 

 

 

Configuration 

 

 

No.  Name 

1  Body 

2  Separator Body 

3  Cover 

4  Separator 

5  Body Gasket 

6  Guide Pin 

7  Body Bolt 

8  Cover Bolt 

9  Cover Gasket 

10  Wave Spring   

11  Float Cover   

12  Float Cover Bolt 

13  Spring Washer 

14  Nameplate 

15  Flange 

(15 

– 25 mm (

1

/

2

 

– 1 in) 

 

 

 

 

DO NOT use for toxic, flammable or otherwise hazardous fluids.

This product is a separator for steam or air that separates and 

discharges condensate from steam or air piping systems. Use only for 

steam, air and/or condensate. This product is for intended use only. 

Improper use may result in such hazards as damage to the product or 

malfunctions that may lead to serious accidents.

WARNING

Model

Production Lot No.

Maximum Allowable
Temperature (TMA)*

Maximum Operating
Temperature (TMO)

Nominal Diameter

Maximum Allowable

Pressure*

Maximum Operating

Pressure

Valve No.**

Air/Steam Trap Outlet

Separator
Outlet

Condensate

Outlet

Separator
Outlet

Summary of Contents for DC3

Page 1: ...172 65236MA 04 DC3 L 7 October 2021 Cyclone Separator DC3 L Copyright 2021 by TLV CO LTD All rights reserved ...

Page 2: ...ance to make sure nothing is out of the ordinary Also be sure to read this manual carefully before use and follow the instructions to be sure of using the product properly This cyclone separator uses centrifugal force to separate condensate from air or steam in piping lines If detailed instructions for special order specifications or options not contained in this manual are required please contact...

Page 3: ...m Indicates an urgent situation which poses a threat of death or serious injury Indicates that there is a potential threat of death or serious injury Indicates that there is a possibility of injury or equipment product damage DO NOT use for toxic flammable or otherwise hazardous fluids This product is a separator for steam or air that separates and discharges condensate from steam or air piping sy...

Page 4: ...components when repairing the product and NEVER attempt to modify the product in any way Failure to observe these precautions may result in damage to the product and burns or other injury due to malfunction or the discharge of fluids Do not use excessive force when connecting threaded pipes to the product Over tightening may cause breakage leading to fluid discharge which may cause burns or other ...

Page 5: ...yed for products with options This item is omitted from the nameplate when there are no options Configuration No Name 1 Body 2 Separator Body 3 Cover 4 Separator 5 Body Gasket 6 Guide Pin 7 Body Bolt 8 Cover Bolt 9 Cover Gasket 10 Wave Spring 11 Float Cover 12 Float Cover Bolt 13 Spring Washer 14 Nameplate 15 Flange 15 25 mm 1 2 1 in DO NOT use for toxic flammable or otherwise hazardous fluids Thi...

Page 6: ...ng scraps dirt and oil Close the inlet valve after blowdown 3 Install the product at the point on the piping where the separation of condensate will have the greatest effect on efficiency For example on a steam or air main or branch at the inlet of equipment requiring high quality dry steam or air 4 Install the product so the arrow on the product is pointing in the direction of flow 5 The product ...

Page 7: ...e surface of the product has cooled to room temperature Disassembling or removing the product when it is hot or under pressure may lead to discharge of fluids causing burns other injuries or damage CAUTION Use the following procedures to remove components Use the same procedures in reverse to reassemble Installation inspection maintenance repairs disassembly adjustment and valve opening closing sh...

Page 8: ...ert it into the groove in the separator body Wave Spring Remove with the separator Insert it into the groove Body Gasket Remove the gasket and clean sealing surfaces Replace with a new gasket Table of Tightening Torques Part Size Torque Distance Across Flats mm in N m lbf ft mm in Body Bolt 15 40 1 2 11 2 60 44 17 21 32 50 2 70 51 19 3 4 Cover Bolt 15 40 1 2 11 2 60 44 17 21 32 50 2 70 51 19 3 4 F...

Page 9: ...ns other injuries or damage CAUTION When the product fails to operate properly use the following table to locate the cause and remedy Problem Cause Remedy Steam or air is leaking from sealing surfaces Gasket deterioration or damage Replace with new gasket s Improper tightening torques were used Tighten to the proper torque Water is mixed in with the steam or air from the separator outlet Steam air...

Page 10: ...yond the control of TLV TII or TLV group companies or 6 improper storage maintenance or repair or 7 operation of the Products not in accordance with instructions issued with the Products or with accepted industry practices or 8 use for a purpose or in a manner for which the Products were not intended or 9 use of the Products in a manner inconsistent with the Specifications or 10 use of the Product...

Page 11: ...SASSEMBLY AND SHIPMENT OF THE DEFECTIVE PRODUCT INJURY TO OTHER PROPERTY DAMAGE TO BUYER S OR THE FIRST END USER S PRODUCT DAMAGE TO BUYER S OR THE FIRST END USER S PROCESSES LOSS OF USE OR OTHER COMMERCIAL LOSSES WHERE DUE TO OPERATION OF LAW CONSEQUENTIAL AND INCIDENTAL DAMAGES UNDER THIS WARRANTY UNDER ANY OTHER EXPRESS WARRANTY NOT NEGATED HEREBY OR UNDER ANY IMPLIED WARRANTY NOT NEGATED HEREB...

Page 12: ...ad Nunawading Victoria 3131 Australia Tel Fax 61 0 3 9873 5610 61 0 3 9873 5010 In East Asia 36 Kaki Bukit Place 02 01 02 Singapore 416214 Tel Fax 65 6747 4600 65 6742 0345 Room 5406 No 103 Cao Bao Road Shanghai China 200233 Tel Fax 86 0 21 6482 8622 86 0 21 6482 8623 No 16 Jalan MJ14 Taman Industri Meranti Jaya 47120 Puchong Selangor Malaysia Tel Fax 60 3 8065 2928 60 3 8065 2923 252 94 K L 17th ...

Reviews: