172-65236MA-04 (DC3-L) 7 Oct 2021
8
Troubleshooting
When disassembling or removing the product, wait until the internal
pressure equals atmospheric pressure and the surface of the product
has cooled to room temperature. Disassembling or removing the
product when it is hot or under pressure may lead to discharge of fluids,
causing burns, other injuries or damage.
CAUTION
When the product fails to operate properly, use the following table to locate the
cause and remedy.
Problem
Cause
Remedy
Steam or air is
leaking from
sealing surfaces
Gasket deterioration or damage
Replace with new gasket(s)
Improper tightening torques were
used
Tighten to the proper torque
Water is mixed in
with the steam or air
from the separator
outlet
Steam/air flow velocity is too high Take steps necessary to lower the
steam/air flow velocity
Improper installation