EF200R-C
35
Environment
Ambient temperature range
Compact version
Measuring device
‒40 to +80
°
C (‒40 to +176
°
F)
Local display
‒40 to +70
°
C (‒40 to +158
°
F)
1)
1)
At temperatures < ‒20
°
C (‒4
°
F), depending on the physical characteristics involved, it may no longer
be possible to read the liquid crystal display.
Remote version
Transmitter
‒40 to +80
°
C (‒40 to +176
°
F)
Sensor
‒40 to +85
°
C (‒40 to +185
°
F)
Local display
‒40 to +70
°
C (‒40 to +158
°
F)
1)
1)
At temperatures < ‒20
°
C (‒4
°
F), depending on the physical characteristics involved, it may
no longer be possible to read the liquid crystal display.
►
If operating outdoors:
Avoid direct sunlight, particularly in warm climatic regions.
You can order a weather protection cover from TLV.
Storage temperature
All components apart from the display modules:
-
50 to
+
80
°
C (
-
58 to
+
176
°
F)
Climate class
DIN EN 60068-2-38 (test Z/AD)
Degree of protection
Transmitter
• As standard: IP66/67, type 4X enclosure
• When housing is open: IP20, type 1 enclosure
• Display module: IP20, type 1 enclosure
Sensor
IP66/67, type 4X enclosure
Connector
IP67, only in screwed situation
Vibration- and shock-
resistance
Vibration sinusoidal, according to IEC 60068-2-6
• 2 to 8.4 Hz, 7.5 mm peak
• 8.4 to 500 Hz, 2 g peak
Vibration broad-band random, according to IEC 60068-2-64
• 10 to 200 Hz, 0.01 g
2
/Hz
• 200 to 500 Hz, 0.003 g
2
/Hz
• Total: 1.67 g rms
Shock half-sine, according to IEC 60068-2-27
6 ms 50 g
Rough handling shocks according to IEC 60068-2-31
Electromagnetic
compatibility (EMC)
As per IEC/EN 61326 and NAMUR Recommendation 21 (NE 21)
Details are provided in the Declaration of Conformity.