172-65427MA-05 (JH7RH-P/JH7RHT-P) 29 Sep 2016
10
Detaching/Reattaching Components Inside the Body
Part
During Disassembly
During Reassembly
Snap Ring
Pinch the insides together and
remove from the body
Insert securely into the slot in the
body
Screen
Remove by grasping the wire ring
and lifting straight up and out
Set the screen on the screen holder
and screen holder retainer and insert
as far as the snap ring groove
Screen Holder
Retainer
Remove without bending
Set on the screen holder without
tilting
Screen Holder Remove without bending
Place on the ledge inside the body,
making sure that the rounded side is
on top
Float
Remove, being careful not to
scratch the polished surface
Insert, being careful not to scratch the
polished surface
Outlet Cover
Nut
Remove with a socket wrench
Consult the table of tightening torques
and tighten to the proper torque
Outlet Cover
Remove, being careful not to
scratch the gasket sealing
surfaces
Make sure there are no pieces of the
old gasket left on the sealing surfaces
and reattach
Outlet Cover
Gasket
Remove the gasket and clean the
sealing surfaces
Replace with a new gasket
Orifice Locknut Remove with a socket wrench
Consult the table of tightening torques
and tighten to the proper torque –
see NOTE below
Orifice
Pull out from inside the trap body
Fix with the orifice locknut – see
NOTE below
Orifice Gasket Remove, being careful not to scratch
the orifice
Replace with a new gasket; clean the
sealing surface on the orifice –
see NOTE below
NOTE: Special points pertaining to orifice and orifice gasket reassembly
Follow the steps below when inserting the orifice into the body in order to ensure that
the gasket does not fall off and is inserted correctly without protruding from the groove.
1. First, insert the orifice alone into the orifice-housing section of the body, in order
to ascertain how much of it should be sticking out.
2. Take the orifice out again, and then fill the groove in the orifice with water and
insert the gasket. The surface tension of the water will now hold the gasket in
place, and it will not fall out even if the orifice is pointed downwards.
3. Without altering anything, insert it into the orifice-housing section of the body and
check to make sure that the amount of orifice sticking out of the body is the same
as the amount that was sticking out when only the orifice was inserted in step 1.
4. Hold it in that position by hand and, after hand-tightening the orifice locknut from
the outlet side, hold the orifice in place from the body float chamber side using a
drive wrench and then tighten the orifice locknut to the proper torque using a
torque wrench.