5.4.3
Connecting Tool End Digital Input
The following figure shows how to connect the tool end digital input:
NOTE: If sensors are connected directly then they should be NPN.
Figure 57: Connecting Tool End Digital Input
5.4.4
Connecting Tool End Analog Input
Range
Resolution
Accuracy
Conversion Time
+10.00V~-10.00V
11bit
≤ 0.2%
1 ms
Table 16: Analog Input Range
The following figure shows how to connect the tool end Analog input:
(Because AIN_GND is connected to ground, when AIN is a dead contact, a pressure difference will
occur, which is a normal phenomenon.)
Figure 58: Connecting Tool End Analog Input
-
+