MAINTENANCE

1.  Regularly check all connections to make sure they are secure and that the EASI-Dose 

Plus

unit is functioning correctly.

2.  During routine maintenance, the dosing pump heads and the silicone hosing must be

checked for any signs of wear or degradation and must be replaced accordingly. Failure to

do so could result in dosing inaccuracies, operating problems and damage to the dosing

pump. Spares are available from your local stockist. These consumable items are not

covered under the 12 month guarantee (please see back page for details on all available

accessories and spares).

REPLACING THE DOSING PUMP HEAD

1.  To replace the dosing pump head, squeeze the left and right tabs

either side of the head and gently but firmly pull the pump head

forward.

2.  To replace, ensure the pump shaft sits centrally in the dosing

pump head and push onto the EASI-Dose 

Plus

unit, ensuring the

clips are aligned left and right. Firmly push the dosing pump head

on until it clicks into place. Check the pump head is operational

by pressing and holding button D (Manual Feed/+) until liquid is

successfully passing through.

Summary of Contents for REEF EASI-Dose Plus 1

Page 1: ...FOR ADVANCED AQUARISTS BY TMC FOR ADVANCED AQUARISTS B BY TMC TMC...

Page 2: ......

Page 3: ...it is malfunctioning or if it has been dropped or damaged in any way This unit is designed to be used indoors and is not suitable for any outdoor applications Ensure the EASI Dose Plus dosing system...

Page 4: ...or accurately measuring 10ml TECHNICAL SPECIFICATION Power Consumption 4W Max Flow 60ml minute Motor Speed 3800rpm Accuracy 5 PARTS LIST 1 LCD display 2 Dosing pump head 3 Silicone hosing 3m 4 Inlet l...

Page 5: ...3 1 2 10 5 4 4 4 4 4 4 4 4 4 4 3 6 7 7 7 8 8 8 9 7 6 6 6 3 3 5 5 5 5 5 5 5 5 5 2 2 2 2 2 2 2 1 1 1112 13 10 11 12 13 10 11 12 13 14...

Page 6: ...engths of hosing are long enough to connect your liquid storage containers to the inlet s 4 on the dosing pump head s 1 and to connect the outlet s 5 to your desired dosing location without any kinks...

Page 7: ...olled from the Master system EASI Dose Plus 1 2 or 3 giving you up to 8 additional pumps If you wish to expand your EASI Dose Plus Master system simply connect an EASI Dose Plus Slave sold separately...

Page 8: ...doser to running mode the on the clock will flash whilst in running mode but not whilst in setting mode B Dose t Button This button will allow you change the dose quantity in ml and also scroll to the...

Page 9: ...set when to dose Each pump can deliver your determined dosing volume up to 24 times per day on each hour should you require it Each pump will start approximately 3 minutes after the previous one in o...

Page 10: ...8 Example Settings Pump No 1 DosingVolume 10ml Dosing Times 08 00 12 00 16 00 Pump No 2 DosingVolume 20ml Dosing Times 04 00 08 00 12 00 16 00 20 00 Pump No 3 DosingVolume 100ml Dosing Times 12 00...

Page 11: ...anually dose additives as and when required CALIBRATINGYOUR EASI DOSE MASTER ALL MODELS The calibration process is based on calibrating to a 10ml dosing volume The calibration process should be carrie...

Page 12: ...eved IFTHE DOSEDVOLUME IS MORETHAN 10ML 12 If the dosed volume is more than 10ml press the Dose button 2 to reduce the DoseVol ea from 100 to 99 13 Empty the liquid from the measuring vessel place the...

Page 13: ...consumable items are not covered under the 12 month guarantee please see back page for details on all available accessories and spares REPLACINGTHE DOSING PUMP HEAD 1 To replace the dosing pump head...

Page 14: ...ect the rollers the silicone hosing and the inside of the dosing pump head for wear Replace any parts that are worn 3 Wrap the silicone tubing around the rolling wheel and re insert into the dosing pu...

Page 15: ...osing on the hour Solution Each pump will run in order with approximately a 3 minute gap between doses This ensures your liquids will mix correctly and will help to stop precipitation of balling salts...

Page 16: ...5L 9535 EASI Dose Plus 3 EASI Dose Plus Slave Tropical Marine Centre Solesbridge Lane Chorleywood Hertfordshire WD3 5SX UK Technical Information Lines Tel 44 0 1923 284151 Fax 44 0 1923 285840 Open b...

Reviews: