background image

7

SETTING THE CURRENT TIME

1.  Press button C (Time/

u

) to enter current time. The clock will flash whilst in the settings

mode.

2.  Press button C (Time/

u

) again to scroll through the hours and minutes (selected item will

flash) and using button D (Manual Feed/+) increase the hours/minutes to the correct time.

3.  Press button A (Pump/OK) to confirm and save the current time.

SETTING DOSING VOLUME

1.  Press button A (Pump/OK) a number of times to scroll through all pump numbers until you

find the pump you wish to set dosing details for.

2.  Press button B (Dose/

t

) to enter the dosing volume setting.

3.  Press button D (Manual Feed/+) to adjust the first two digits (from 1 - 19) of the dosing

volume and then press button C (Time/

u

) to move onto the third digit of the dosing

volume and adjust using button D (Manual Feed/+) (1 - 9). For example, if you wanted to set

the dosing volume to 149ml, you would set the first two digits to 14 and the third digit to 9.

Please Note: 

Dosing volume can be set from 1ml to 199ml per dose.

SETTING DOSING TIMES

After setting your dosing volume you can set 

when

to dose. Each pump can deliver your

determined dosing volume up to 24 times per day, on each hour, should you require it. Each

pump will start approximately 3 minutes after the previous one in order to allow time for

your chosen additives to mix with your aquarium water. For example if you set two pumps to

dose at 10am, the first will dose at 10am and the second will dose at approximately 10.03am.

1.  After setting your dosing volume press button C (Time/

u

) to scroll through to the ‘when

to dose’ section of the screen. 1 to 24 represents each hour of the day in 24hr time

format. Press button C (Time/

u

) to scroll right, or button B (Dose/

t

) to scroll left. An

hour time slot will flash then you are able to select/deselect it.

2.  Use button D (Manual Feed/+) to select/deselect the hours when you would like the

pumps to dose. The selected hours will be underlined when the button is pressed and will

be deselected by pressing button D (Manual Feed/+) again. No line will show under the

number when it is deselected.

3.  Repeat the above process for all dosing pumps and then press and hold down button A

(Pump/OK) for 2 seconds to confirm and save the settings for all pumps.  The dosing unit

will now be in running mode and the ‘:’ on the clock will now be flashing.

Summary of Contents for REEF EASI-Dose Plus 1

Page 1: ...FOR ADVANCED AQUARISTS BY TMC FOR ADVANCED AQUARISTS B BY TMC TMC...

Page 2: ......

Page 3: ...it is malfunctioning or if it has been dropped or damaged in any way This unit is designed to be used indoors and is not suitable for any outdoor applications Ensure the EASI Dose Plus dosing system...

Page 4: ...or accurately measuring 10ml TECHNICAL SPECIFICATION Power Consumption 4W Max Flow 60ml minute Motor Speed 3800rpm Accuracy 5 PARTS LIST 1 LCD display 2 Dosing pump head 3 Silicone hosing 3m 4 Inlet l...

Page 5: ...3 1 2 10 5 4 4 4 4 4 4 4 4 4 4 3 6 7 7 7 8 8 8 9 7 6 6 6 3 3 5 5 5 5 5 5 5 5 5 2 2 2 2 2 2 2 1 1 1112 13 10 11 12 13 10 11 12 13 14...

Page 6: ...engths of hosing are long enough to connect your liquid storage containers to the inlet s 4 on the dosing pump head s 1 and to connect the outlet s 5 to your desired dosing location without any kinks...

Page 7: ...olled from the Master system EASI Dose Plus 1 2 or 3 giving you up to 8 additional pumps If you wish to expand your EASI Dose Plus Master system simply connect an EASI Dose Plus Slave sold separately...

Page 8: ...doser to running mode the on the clock will flash whilst in running mode but not whilst in setting mode B Dose t Button This button will allow you change the dose quantity in ml and also scroll to the...

Page 9: ...set when to dose Each pump can deliver your determined dosing volume up to 24 times per day on each hour should you require it Each pump will start approximately 3 minutes after the previous one in o...

Page 10: ...8 Example Settings Pump No 1 DosingVolume 10ml Dosing Times 08 00 12 00 16 00 Pump No 2 DosingVolume 20ml Dosing Times 04 00 08 00 12 00 16 00 20 00 Pump No 3 DosingVolume 100ml Dosing Times 12 00...

Page 11: ...anually dose additives as and when required CALIBRATINGYOUR EASI DOSE MASTER ALL MODELS The calibration process is based on calibrating to a 10ml dosing volume The calibration process should be carrie...

Page 12: ...eved IFTHE DOSEDVOLUME IS MORETHAN 10ML 12 If the dosed volume is more than 10ml press the Dose button 2 to reduce the DoseVol ea from 100 to 99 13 Empty the liquid from the measuring vessel place the...

Page 13: ...consumable items are not covered under the 12 month guarantee please see back page for details on all available accessories and spares REPLACINGTHE DOSING PUMP HEAD 1 To replace the dosing pump head...

Page 14: ...ect the rollers the silicone hosing and the inside of the dosing pump head for wear Replace any parts that are worn 3 Wrap the silicone tubing around the rolling wheel and re insert into the dosing pu...

Page 15: ...osing on the hour Solution Each pump will run in order with approximately a 3 minute gap between doses This ensures your liquids will mix correctly and will help to stop precipitation of balling salts...

Page 16: ...5L 9535 EASI Dose Plus 3 EASI Dose Plus Slave Tropical Marine Centre Solesbridge Lane Chorleywood Hertfordshire WD3 5SX UK Technical Information Lines Tel 44 0 1923 284151 Fax 44 0 1923 285840 Open b...