TROUBLE SHOOTING
Problem: The filter media is not fluidising correctly.
1. Possible Cause: Water flow rate to the filter is incorrect.
Solution: Adjust water flow to the filter accordingly.
2. Possible Cause: Pump/power filter is not plugged in or is not operating correctly.
Solution: Refer to the instructions supplied with your pump/power filter.
3. Possible Cause: Air is trapped inside the filter
Solution: Switch off your pump/power filter. Wait for a few minutes for the air to escape and
the media to settle to the bottom of the filter and then switch the pump or power filter
back on and adjust the water flow accordingly.
4. Possible Cause: Water inlet (6), water inlet 90° elbow hosetail assembly (5), water outlet (7)
or water outlet pipe assembly (9) is blocked.
Solution: Check for blockage and clean accordingly.
5. Possible Cause: The filter media needs replacing.
Solution: Replace filter media accordingly.
PLEASE READ CAREFULLY
IF USING THIS UNIT WITH PHOSPHATE REMOVING MEDIA
1. If using phosphate removing media we highly recommend that it is GENTLY rinsed
before use to remove excess dust etc.
2.
Please Note:
The water flow to the filter must be carefully adjusted to ensure that
the phosphate removing media is not being fluidised too vigorously and that the media
is only gently fluidised. Failure to do so could result in over-abrasion of the phosphate
removing media and fine particles or dust being passed into the aquarium or sump.
3. Check regularly that the filter is functioning properly and the phosphate removing
media is being fluidised correctly i.e not too vigorously, and that the phosphate
removing media is not clumping together.
4. Replace phosphate removing media according to instructions provided with the media.
7