CONNECTIONTOTHE AQUARIUM WATER SUPPLY

Water flow:

There is no correct flow direction through the unit. Either port

may be used as the inlet or outlet.

Connection with flexible hose

The V

2

ecton unit is supplied with two universal hosetails to take

1/

2

”,

3/

4

”, 1”and 1

1/

4

diameter flexible hose. If you are using one of the three larger sizes, the smaller

sections of the hosetails must be cut off to ensure sufficient water flow and to

prevent possible damage to the pump. We recommend that you use the largest

diameter hose available. As it is easier to cut the hosetails while they are attached to

the unit, attach them using the female threaded lock nuts and gaskets provided. Ensure

that the gaskets are seated correctly between the flat face of the hosetails and the flat

face of the inlet/outlet ports. Using a hacksaw, carefully cut off the excess hosetail,

ensuring that the sections are cut off at the second ridge and that the cut follows the

line of the ridge.

Once trimmed, hand tighten the lock nuts to secure the hosetails to the inlet/outlet ports.

Do not use jointing compound or PTFE tape. Secure the hosepipe to the hosetail

with a stainless steel hose clip.

The hosetails supplied are made from a translucent material which will glow when the

unit is operating correctly. (NB. glow only visible in low levels of light.)

Connection using rigid pipe

This unit may also be rigid plumbed in either of the following ways:-

1.

Using TMC universal rigid pipe adaptors

available from your aquatic

supplier (part no. PCADRPACTO4)

.

These should be fitted as shown in the diagram below.

A. If using 40mm solvent weld plastic pipe the adaptor will be glued into the

pipe. It is essential to fit the lock nut before you solvent weld the adaptor

into the 40mm pipe. When solvent welding the two parts, sufficient space

(20mm as shown) must be left between the adaptor and the 40mm pipe

to allow the lock nut to be undone.

B. If using 1” solvent weld pipe the pipe will be glued into the adaptor at the

first stepped stage.

C. If using 32mm solvent weld pipe the pipe will be glued into the adaptor at

the second stepped stage.

Important:

Once you have solvent welded the two parts they must be left to

fully cure before making the final connection between the rigid pipe adaptor

and the V

2

ecton. When attaching the plumbed rigid adaptors to the unit ensure

that the gaskets are seated correctly between the flat face of the pipe adaptor

and the flat face of the inlet/outlet ports. Do not use a jointing compound or

PTFE tape.

For USA rigid plumbing you should use the 1” pipe option above.

2.

Using 1

1

/

2

" BSP female threaded plastic sockets

that are available from

most suppliers of plastic plumbing fittings.

2

Gasket

Lock Nut

20mm

40mm solvent

weld plastic pipe

1” or 32mm solvent

weld plastic pipe

CUT

LINE

CUT

LINE

CUT

LINE

Gasket

Lock Nut