W W W . T M G I N D U S T R I A L . C O M
P 0 8 / 2 8
T o l l F r e e : 1 - 8 7 7 - 7 6 1 - 2 8 1 9
4 Foot Level
Small Adjustable Wrench
TOOLS REQUIRED
Large Adjustable Wrench
12mm Hex Key
IMPORTANT NOTICE !
These instructions must be followed to ensure proper installation and operation of your lift.
Failure to comply with these instructions can result in serious bodily harm and void product
warranty. Manufacturer will assume no liability for loss or damage of any kind, expressed or implied
resulting from improper installation or use of this product.
PLEASE READ ENTIRE MANUAL PRIOR TO INSTALLATION !
STEP 1
(Selecting Site)
Before installing your new lift, check the following.
1.
LIFT LOCATION: Always use architects plans when
available. Check layout dimension against floorplan
requirements making sure that adequate space if avail-
able.
2.
OVERHEAD OBSTRUCTIONS: The area where the
lift will be located should be free of overhead obstruc-
tions such as heaters, building supports, electrical lines
etc.
3.
DEFECTIVE FLOOR: Visually inspect the site where
the lift is to be installed and check for cracked or defec-
tive concrete.
4.
OPERATING TEMPERATURE. Operate lift only
between temperatures of 41° -104° F.
5.
Lift is designed for INDOOR INSTALLATION ONLY.
STEP 2
(Floor Requirements)
This lift must be installed on a solid level concrete
floor with no more than 3-degrees of slope. Failure
to do so could cause personal injury or death.
A level floor is suggested for proper use and installa- tion
and level lifting. If a floor is of questionable slope,
consider a survey of the site and/or the possibility of
pour- ing a new level concrete slab.
DO NOT install or use this lift on any asphalt surface
or any surface other than concrete.
DO NOT install or use this lift on expansion seams
or on cracked or defective concrete.
DO NOT install or use this lift on a second / elevated
floor without first consulting building architect.
DO NOT install or use this lift outdoors.
CONCRETE SPECIFICATIONS
LIFT MODEL
CONCRETE REQUIREMENTS
TMG-ALS61
3.5” Min. Thickness / 2,500 PSI
DANGER!
All models MUST be installed on 3,000 PSI concrete only
conforming to the minimum requirements shown above.
New concrete must be adequately cured by at least
28 days minimum.