WWW.TMGINDUSTRIAL.COM
19 / 27
dŽůů&ƌĞĞ
:1-887-761-2819
O P E R A T I O N
6.
Ensure the blade is properly oriented, with the leading edge out. The blade is designed to fit into the
rotor one way only. See diagram for proper installation.
7.
Tighten down bolts as specified in the torque chart.
8.
Repeat steps for remaining blades.
Ledger Blades:
The TMG-WC62S is equipped with a ledger (stationary) blade that acts as a shear for the moving rotor
blades. The ledger blade is designed with 4 usable corners. When the corner facing the rotor blade rounds
over, remove the blade and reinstall with a different corner facing the rotor blade. It is recommended that the
clearance between the rotor and stationary blades be set and maintained at 1/32 to 1/16 " (.76 - 1.52 mm) to
obtain the best performance.
1.
Turn off the hydraulics, stop the engine, remove the
ignition key and place it in your pocket and wait for
all moving parts to stop.
2.
Remove the 2 bolts that hold the ledger blade to the
ledger mount, remove the blade.
3.
Rotate the blade and replace or replace with new or
re-sharpened blade.
4.
Hand tighten the bolts and set the clearance between the ledger and rotor blades at 1/32 - 1/16" .
5.
Tighten down bolts as specified in the torque chart