- 11 -
■ F04 : Automatic Zero Condition (00~99)
Setting Menu
Description
F04-00
No compensation
F04-23
Compensation for gradual change below 1d for 3 sec.
F04-99
Compensation for gradual change below 4.5d for 9 sec.
■ F05 : Adjustment the hold speed (1~9)
Setting Menu
Description
F05-1
Very fast
F05-5
Normal
F05-9
Very slow
■ F06 : Auto Hold Start (0,1)
Setting Menu
Description
F06-0
Manual
F06-1
Automatic
■ F07 : Initialization Hold Weight (1~9)
Setting Menu
Description
F07-0
Zero (0)
F07-3
Below 3 division
F07-9
Below 9 division
■ F08 : Function * key (0~3)
Setting Menu
Description
F08-0
FND Type: Not used.
LCD Type: Back light ON/OFF
F08-1
Print command key
F08-2
18byes weighing data send key
F08-3
Use to clear previously added weights.