background image

3.2.

 

Provider and operator duties 

 

 

The  provider  may  allow  the  work  with  the  source  only  to  the  persons,  who  are 
informed  about  the  safety  regulations,  trained  in  the  source  manipulation  and 
informed about the source operating instructions. 
The  person  authorized  to  work  with  the  source  is  obligated  to  follow  all  basic 
regulations about safety of operation, with special regard to warnings given in these 
operating instructions. 
 

 

3.3.

 

Personal protective outfit 

 

 

The  source  operator  must  have  strong  working  shoes,  which  also  insulate  in  wet 
environment,  protective  working  gloves,  shield  with  protective  filter  for  eyes 
protection, suitable hardly flammable clothes and aural protectors at increased noise 
level. 
When other persons are in the source vicinity, they must be instructed about possible 
danger,  have  the  protective  equipment  available,  possibly  they  must  be  protected 
with protective curtains or screens. 
When some animals move within the reach of the welding workplace, it is necessary 
to adopt measures for their protection, the animals must be prevented from access to 
the welding workplace.    
 

 
3.4. Risks resulting from the action of harmful vapours and gases  

 
The  smoke  and  harmful  vapours  occurring  during  the  welding  are  deleterious.  It  is 
necessary  to  exhaust  them  using  suitable  equipment  and  at  the  same  time  it  is 
necessary to ensure sufficient supply of fresh air.  
 

3.5. Risks resulting from flying off sparks

  

 
It is necessary to remove all flammable objects from the source working area. 
Volatile,  flammable  matters,  whose  vapours  are  easily  inflammable,  are  especially 
dangerous. 
No welding works can be carried out in the area serving for storage of gases, fuel, 
oils  and  similar  matters,  because  also  the  remains  of  these  matters  represent 
explosion and fire risk. 
Special  regulations  apply  in  area  with  fire  and  explosion  risk  –  therefore  their 
consistent following is necessary. 
 

3.6.

 

Other necessary measures

 

 

Welding sources are generally in the term of interference voltage designated for work 
in the industrial area. When it is used in the living space, special measures are 
necessary for elimination of the interference. Therefore the user is obligated to 
evaluate whether he cannot cause electromagnetic problems in vicinity at the source 
installation. In the first place it is necessary to consider aspect of signal and 
telecommunication leads, radio and television receivers and transmitters, computers, 

Summary of Contents for TT 350 mig/mag

Page 1: ...ating instructions of the welding inverter TT 350 mig mag Content 1 Description 2 Technical data 3 Safety regulations 4 Thermal and short circuit protection 5 Putting into operation 6 Maintenance 7 Disposal ...

Page 2: ... standard On the front panel there are quick plugs for connection of the welding cables a euro terminal for connection of the welding torch for setting of the optimal welding parameters for the individual welding technologies two digital measuring devices and three LEDs The source cooling is forced with a ventilator 1 2 Controls Positions and names of the individual controls are given in the pictu...

Page 3: ... determined for 25o C X D determines the time during which the source can be loaded by the given welding current without the thermal protection making any reactions This time refers to 10 minute working cycle 3 Safety regulations 3 1 Introduction The source is made in accordance with the present technical knowledge and safety requirements Nevertheless there is a danger of health or life hazard of ...

Page 4: ...ks resulting from the action of harmful vapours and gases The smoke and harmful vapours occurring during the welding are deleterious It is necessary to exhaust them using suitable equipment and at the same time it is necessary to ensure sufficient supply of fresh air 3 5 Risks resulting from flying off sparks It is necessary to remove all flammable objects from the source working area Volatile fla...

Page 5: ...immediate removal of failures and defects reported by the source operator to ensure regular inspections of the source to ensure regular revisions of the source in terms of ČSN 33 1500 and ČSN EN 05 0630 3 9 Regular inspections The aim of the inspection is to ensure failure free operation of the source The inspection term is given with regard to frequency of use and environment in which the source ...

Page 6: ... slip connections their possible tightening or repair Control visually whether the mechanical parts are not released or the safe air distances and surface ways are not disturbed Possible defects must be removed prior to further use b Control of the guard wire The guard wire must not be damaged or interrupted Test the strength of individual interconnections on the connections and connectors by hand...

Page 7: ...low it to cool down The thermal protection automatically restores the source function after cooling down and the yellow indicator TEMP is off ATTENTION After the thermal protection effect put the electrode holder on insulated place so that accidental short circuit could not occur after restoring of the source function and thus a possible accident or damage to property could not occur 4 2 Short cir...

Page 8: ...ldment as near to the welded place as possible 5 1 3 Source connection to supply mains The source is constructed for connection to 5 conductor main TN C S with voltage 3x400V 50Hz see point 2 Installation of the main plug for the source connection and its protection must correspond to the valid standards and electro technical regulations 5 2 Welding process MMA connect the source to the supply mai...

Page 9: ...s MIG MAG switch over the switch 20 into the position 0 disconnect the source from the supply mains by pulling out the fork of the supply 5 3 1 Assembly of the gas bottle Important only a gas bottle with height max 120 cm can be fixed to the source put the bottle on the platform 25 put the bottle into the strap 19 and secure with a chain unscrew the protective cover of the gas bottle remove the se...

Page 10: ... of the pulley mechanism into the leading tube of the torch in length ca 5 cm check whether the wire locked into the grooves in the feeding pulleys when pressing the levers with the pressing pulleys tip over the tension device into a vertical position adjust the pressure using a screw shackle so that the wire electrode could not be deformed and good feeding could be ensured at the same time put a ...

Page 11: ...ertical position 5 3 6 Preparation of the source for welding setting of the welding parameters The source is prepared according to points 5 3 1 to 5 3 5 connect the ground welding cable into the plug 13 and connect to weldment switch over the power switch of the source 20 into the position I check the position of the switch 9 MIG MAG the switch 14 2T press the button 5 segment at m min setting of ...

Page 12: ...ch button after the set time the process finishes automatically the process is repeated by releasing and new pressing of the torch button The switch of the potentiometer 11 must be switched off position 0 for use of the continuous mode of the welding 5 3 10 Process of cyclic welding It is switched on and set with the potentiometer 11 and 12 set the time of the arc burning with the potentiometer 11...

Page 13: ...pressing of the button 4 PROG 5 3 13 Accessing the welding parameters MIG MAG from memory switch over the switch of the welding procedures 9 into the position PROG MIG briefly press the button 4 PROG Pxx is displayed on the lower display list the number of the program whose parameters we want to weld using the button 5 wait for short time until the parameters are displayed start welding 5 4 Weldin...

Page 14: ...le from the plug 6 1 Everyday control This activity is carried out by the source operator It is checked state of the main cable state of the welding cables and torch cleanness of the source 6 2 Regular special inspections The control is made by a worker determined by the source owner for this activity The worker must have a corresponding electro technical qualification When inspecting the worker f...