background image

7

6. CONNECTIONS

6.1. Removable Terminal Plug Connection

Notes

• Avoid soldering cable conductor, as contact resistance may increase when the cable is tightened and the

solder is crushed, possibly resulting in an excessive rise in joint temperatures.

• Use cables of AWG 12 – 24.

[Cable end treatment]

7 mm

7 mm

20 mm

2-core shielded cable

Solid cable and stranded cable

[Wiring Procedure]

Step 1.

Wiring the supplied removable terminal plug.

1-1.

Loosen the terminal screws to insert the wire.

1-2.

Tighten the terminal screws.
Ensure that the wire does not break free when pulled. If
the wire does pull free, repeat the connection procedure
from the start.

Step 2.

Insert the wired terminal plug into the corresponding
terminal block in the unit's rear panel.

Step 3.

Tighten the fixing screws. (Speaker output terminals only)

Notes

• Do not reverse 

Steps 1

and 

2

. Poor contact may result if force

is applied to the unit's internal circuit board pins while the
terminal screws are being tightened.

• Use an appropriate type screwdriver for terminal plug wiring.

Removable 
terminal plug 

1

2

3

Tighten

Tighten

6.2. Input Connections

6.2.1. Line input connections

LINE IN

H

E

E

H

Input source

Input source

Input source

H

E

H

E

Upper and lower RCA jacks are internally, passively mixed. 

[Input level selection]

Input sensitivity can be switched to either 0 dB or +4 dB depending on the output level of the
input equipment.

INPUT

LEVEL

0dB

+4dB

Summary of Contents for BA-235

Page 1: ...8 2 CHANNEL BROADCAST 9 9 OPERATION 9 10 INSTALLATION PRECAUTIONS 9 11 RACK MOUNTING BRACKET ATTACHMENT 10 12 VOLUME SETTING 11 13 VOLUME CONTROL COVER 11 14 BLOCK DIAGRAM 11 15 DIMENSIONAL DIAGRAM 12 16 SPECIFICATIONS 12 Accessories 12 Optional products 12 MASTER SIGNAL PEAK POWER ON OFF BASS TREBLE POWER AMPLIFIER BA 260 0 10 Thank you for purchasing TOA s Power Amplifiers Please carefully follo...

Page 2: ...instructions pour référence ultérieure Respecter tous les avertissements Suivre toutes les instructions Ne pas utiliser cet appareil à proximité d eau Nettoyer uniquement à l aide d un chiffon sec Ne pas obstruer les orifices de ventilation Installer conformément aux instructions du fabricant Ne pas installer à proximité de sources de chaleur telles que des radiateurs des registres thermiques des ...

Page 3: ...nter l unité en bâti Retirez les quatre vis M4 x 8 sur les deux côtés de l appareil et montez la patte à l aide des vis M4 x 16 fournies avec la patte When the Unit is in Use Should the following irregularity be found during use immediately switch off the power disconnect the power supply plug from the AC outlet and contact your nearest TOA dealer Make no further attempt to operate the unit in thi...

Page 4: ... up inside the unit and result in fire Avoid installing the unit in humid or dusty locations in locations exposed to the direct sunlight near the heaters or in locations generating sooty smoke or steam as doing otherwise may result in fire or electric shock To avoid electric shocks be sure to unplug the unit s power supply cord when connecting speakers Be sure to follow the instructions below when...

Page 5: ...or flashes intermittently 3 GENERAL DESCRIPTION The BA 235 35 W and BA 260 60 W are Power Amplifiers for background music and general announcement These units are suited for use in bars retail stores and banquet rooms When used in conjunction with the optional mixer amplifier BG 220 20 W or BG 235 35 W 2 channel broadcast can be made 4 FEATURES Remote master volume control using an external volume...

Page 6: ...ternally connected in parallel to the Line input connectors 14 Connect to the other amplifier s input 13 Input level selector switch Selects either 0 dB or 4 dB for the line input sensitivity level 14 Line input terminals 10 kΩ 0 dB 4 dB selectable see item 13 unbalanced removable terminal block and RCA jacks Upper and lower RCA jacks are internally passively mixed 0 dB 1 V These connectors are in...

Page 7: ...e connection procedure from the start Step 2 Insert the wired terminal plug into the corresponding terminal block in the unit s rear panel Step 3 Tighten the fixing screws Speaker output terminals only Notes Do not reverse Steps 1 and 2 Poor contact may result if force is applied to the unit s internal circuit board pins while the terminal screws are being tightened Use an appropriate type screwdr...

Page 8: ...rol 10 kΩ linear taper REMOTE VOLUME 6 3 2 Bridge output connection BRIDGE OUT 10kΩ H E E H Other power amplifier s Line input 6 3 Output Connections 6 3 1 Speaker connections Each amplifier has 3 speaker outputs 4 Ω 25 V and 70 V Use only one of these outputs for connection Class 2 wiring may be used Note Impedances in the figures below represent total speaker load impedance 70 V LINE Total imped...

Page 9: ...e A Sound source B Sound source C LINE IN SPEAKER OUT BA 235 or BA 260 ZONE 2 Sound source C 9 OPERATION After completing all connections turn on the power switch and check to confirm that the power indicator lights Note When the heat sink temperature exceeds 105 C 221 F the protection circuit begins to operate to disconnect the output from the circuit The disconnected output is automatically rest...

Page 10: ...ws on both sides of the unit These removed screws are not used for rack mounting Notes Rack mounting screws are not supplied with the unit Use the screws that are appropriate for the rack When mounting the unit in an equipment rack the inside of the rack must be sufficiently ventilated To achieve sufficient ventilation also mount the optional PF 511 Perforated Panel 1U 1 at the top and the bottom ...

Page 11: ...ront panel it is recommended to replace its control knob with the supplied YA 920 Volume Control Cover Follow the procedure below for its replacement Step 1 Remove the control knob Step 2 Adjust the Master volume control without knob to an appropriate level Step 3 Attach the YA 920 onto the control 14 BLOCK DIAGRAM POWER AMP SPEAKER OUT AC120 V 60 Hz POWER SUPPLY FOR POWER AMP 70 V LINE LINE IN 10...

Page 12: ...movable terminal block Output Regulation 1 kHz Under 2 dB no load to full load S N Ratio Line input Over 80 dB Band Pass 20 Hz 20 kHz Tone Controls Centered Tone Control Bass 10 dB at 100 Hz Treble 10 dB at 10 kHz Control Master gain control Bass tone control Treble tone control Input level selector switch Remote volume control Power ON OFF switch Indicator Power LED Signal level LED Peak LED Othe...

Reviews: