19
• Unit ID of File:
Unit ID of the setting data on the PC
• Slot No.:
Slot number of the module on the unit's rear panel
• Module Settings:
Model of module preserved in memory
• Module Status:
Model of module inserted in unit
If the Module settings and Module status data on a slot do not match, the slot data is highlighted in red as
shown below.
5.7. Confirming the Slot Information
Select [Unit
Slot Information] from the menu to display the Slot Information screen.
The screen offers information on the module settings and the module status while the PC is in communication
with the unit.
Unless the Module settings and Module status data on all slots exactly match with each other, the unit does
not operate correctly.
[Operating the unit according to the Module settings data]
Reinstall modules into the unit according to the module settings data.
[Operating the unit according to the Module status data]
Change the Module settings data according to the following procedures.
Step 1.
Reset the Unit configuration setting on the software without communications between the PC and the
unit.
Select the unit for which you want to change the input/output configuration in the unit view or flow
view.
Select [Unit
Change Unit Configuration...] from the menu to display the Unit Configuration setting
screen. In the same procedures as for creating a new Unit configuration, set the module configuration.
(See
Step 2.
Execute the bulk transmission or make communications with the unit by designating the transfer
direction "PC to Unit" for all data items. (See