56
12. SETTING AND CANCELING GROUPING
Multiple channels can be grouped into each function box of gain, filter, compressor/noise gate, ARC filter,
delay, and mute to make setting values within the group identical or permit values to be adjusted without
changing the relative values within the group. Under the condition that the box on the Flow view has been
selected, grouping can be set or canceled on the menu.
12.1. Setting a Group
Note
Only when ARC boxes are grouped, the unit operation during measurement differs from that in normal use.
For operation during measurement, refer to
Step 1.
Select the boxes to be grouped on the Flow view.
Step 2.
Select [Edit
Set Grouping...] on the menu.
A dialog for group setting is displayed.
Step 3.
Make groups.
3-1.
Making a new group.
Select "New" and press the [OK] button.
Select either "Same Value" or "Keep Offset" and press the [OK] button only for the gain or delay box.
Same Value: Makes values within the group identical.
Keep Offset: Permits values to be changed without changing
the relative values within the group at the time
of group setting.
Summary of Contents for DP-K1