36
[Sequential storage playback]
The unit memorizes up to 16 contact-activated inputs, then each playback is started in the order of input.
The program playback order has no relation to the program priority level. Programs are played in the order of
the activation signal input.
The figure below shows operations of the Sequential storage playback.
Contact-activated input
Contact-activated input
P005 start
Program playback
P005
P014 start
Contact-activated input
P003 start
P014
P003
12.3.4. Forced stop and spontaneous stop of phrase playback
Forced stop:
Stops the program currently being played when the Stop control input
terminal is closed.
Spontaneous stop of phrase playback: Stops the program after the phrase in it currently being played has
ended when the Stop control input terminal is closed.
[Operations of the Forced stop and the Spontaneous stop of phrase playback]
Phrase 00002
Phrase 00001
Program playback
Program playback in progress stops.
P001
Phrase 00002
Phrase 00001
Stop control input
Stop activation
Forced stop
Program playback
Stops after the phrase playback in progress has ended.
P001
Stop control input
Stop activation
Spontaneous stop of phrase playback
Tip: When 2 or more activation signals are simultaneously input, programs are played in the order of program
number.