50
Binary control
Program playback
Contact-activated input P002
Playback control input
Stop control input
P002 playback
P002 selection
Playback start
Stop activation
Contact-activated input P002
Playback control input
Stop control input
Program playback
P002
Phrase 00001 playback Phrase 00002 playback
Stop activation
Playback start
P002 selection
[(18) Forced stop operation by a Pulse signal input activation]
(Activation method)
Program playback currently in operation stops instantly when the Stop control input terminal is closed.
(Operation description)
P002 playback starts when the Playback control input terminal is closed after while the Contact-activated
input terminal is being closed. Program playback stops instantly when the Stop control input terminal is
closed during playback.
Note
Program playback cannot be started while the Stop control input terminal is being closed.
[(19) Spontaneous stop operation of phrase playback by a Pulse signal input activation]
(Activation method)
When the Stop control input terminal is closed, program playback will stop after the phrase playback in the
program currently being played reaches its end.
(Operation description)
P002 playback starts when the Playback control input terminal is closed while the Contact-activated input
terminal is being closed. When the Stop control input terminal is closed during Phrase 00002 playback,
program playback will stop after the phrase playback reaches its end.
Note
Program playback cannot be started while the Stop control input terminal is being closed.