98
Symptom
Possible cause
Remedy
Cannot start recording.
The audio source has already
been registered to the phrase
to which you want to record.
Delete the audio source registered to the
phrase to which you want to record, then
start recording. (See p. 25.)
Memory card is full.
Delete unnecessary audio sources, then
start recording.
Volume level is too small or
no sound is heard even if
recorded sound playback is
started.
Microphone is not correctly
connected to the microphone
input jack or external audio
player to the line input terminal
at the time of recording.
Correctly connect the microphone to the
microphone input jack or external audio
player to the line input terminal, then start
recording.
Input level from the external
audio player to the unit is too
small at the time of recording.
Adjust sound volume of the external audio
player for an appropriate volume level.
(See p. 22, "Recording to Phrase.")
Audio signals are entered
to the input not intended for
recording.
Stop audio signals from entering such input.
Also, set the volume knob of such input to
the minimum position.
Program sound volume is
decreased.
Check the program sound volume using the
EV-700 Setting software.
Or, turn on the AGC using the EV-700
Setting software and the sound volume is
automatically adjusted. (See the EV-700
Setting software instruction manual.)
Volume level is too small
when playing the audio
signals transferred by the EV-
700 Setting software.
Sound volume of wav file is
decreased.
Adjust the sound volume of wav file first,
then transfer the file to the unit.
Or, turn on the AGC using the EV-700 Setting
software and the playback sound volume
is automatically adjusted. (See the EV-700
Setting software instruction manual.)
Program sound volume is
decreased.
Check the program sound volume using the
EV-700 Setting software.
Or, turn on the AGC using the EV-700 Setting
software and the playback sound volume
is automatically adjusted. (See the EV-700
Setting software instruction manual.)
Cannot make external input
broadcasts.
Higher-priority broadcast is
currently being made.
Check the broadcast priority level. (See
the EV-700 Setting software instruction
manual.)
Higher-priority broadcast of the Microphone
broadcast, Line input broadcast, and
Normal broadcast is made preferentially.
Lower-priority broadcast is not made while
higher-priority broadcast is being made.
Microphone is not correctly
connected to the Microphone
input jack or external audio
player to the Line input
terminal.
Correctly connect the microphone to the
Microphone input jack or external audio
player to the Line input terminal.
Input level from the external
audio player to the unit is
decreased.
Adjust the sound level of the external audio
player for an appropriate level. (See p. 84,
"Making the Line input broadcast.")
Adjust the input volume control while
monitoring the level meter.