99
Symptom
Possible cause
Remedy
Busy signal not output.
Contact control output
terminals are not correctly
connected.
Connect the Contact control output
terminals correctly.
Control output and program
playback busy output are not
correctly set.
Set the control output and program playback
busy output using the EV-700 Setting
software. (See the EV-700 Setting software
instruction manual.)
Hiss noise is broadcast.
Microphone input volume
control or Line input volume
control is turned fully
clockwise.
Turn the volume controls fully
counterclockwise when these input
terminals are not used.
Buzzing noise is broadcast.
Functional earth terminal is
not grounded.
Ground the Functional earth terminal.
EV-700 and a PC not placed
online even when connecting
between the two and
activating the EV-700 Setting
software.
LAN cable is not correctly
connected.
Check if LAN cable is correctly connected.
The LINK/ACT indicator lights or flashes
when the cable is correctly connected.
In the case of communication via the
network, check if cables connected to the
switching hub are appropriate ones and
they are connected to the correct port. (See
p. 94.)
FTP communication is
interrupted.
• Check firewall setting.
• To connect the EV-700 online, FTP
communication must be executed.
Consult your network administrator of the
facilities where the EV-700 is installed.
Network setting is not
performed correctly.
See the EV-700 Setting software instruction
manual.
Or, consult your network administrator of the
facilities where the EV-700 is installed.
The "P. WAIT" indication
appears on the Status display.
Some process is in progress
inside the unit, disabling other
processing.
(Examples)
• Other operation was executed
during CF card read.
• Other operation was executed
during recording.
Wait until the internal processing in progress
is complete, then retry operation.
The "Errxx" indication appears
on the Status display.
An error has occurred.
Confirm the remedy in the Error list. (See