30
12.3. Details of the Setting Items
12.3.1. Direct control function and Binary control function
Direct control function: Allows operation such as playback of the program number or recording/deletion of the
phrase number corresponding to such terminal when a make signal is applied to any
one of the Contact-activated input terminals 1 through 16.
Binary control function: Allows selection of 1 to 256 programs by recognizing the open/closed states of the
Contact-activated input terminals 1 through 8 as 8-binary digits.
[Activation by the Direct control function]
For playback start, each of the Contact-activated input terminals 1 through 16 corresponds to the program
number.
For recording start or deletion start, each of the Contact-activated input terminals 1 through 16 corresponds to
the phrase number. (See the table below.)
Contact-activated
input terminal No.
Playback start
Program No.
1
P001
2
P002
3
P003
4
P004
5
P005
6
P006
7
P007
8
P008
9
P009
10
P010
11
P011
12
P012
13
P013
14
P014
15
P015
16
P016
Contact-activated
input terminal No.
Recording/Deletion start
Phrase No.
1
00001
2
00002
3
00003
4
00004
5
00005
6
00006
7
00007
8
00008
9
00009
10
00010
11
00011
12
00012
13
00013
14
00014
15
00015
16
00016
For the details of activation by Direct control function, see p. 39.