33
Unit's playback operation
Contact-activated input
OFF
ON
Program
Unit's playback operation
Stop control input
OFF
ON
Program
Contact-activated input
OFF
ON
Unit's playback operation
Contact-activated input
OFF
ON
Program
12.3.2. Pulse signal input activation and Level signal input activation
Pulse signal input activation: Activates operation when a make signal (Closed time duration: over 50 ms) is
applied to the terminals. Operation stops when it is finished or when a make signal
is applied to the Stop control input.
Level signal input activation: Activates operation when a make signal is applied to the terminals, and continues
the operation while the terminals are being closed.
Playback is repeated when a closed state is maintained even if playback is finished.
[Operation by Pulse signal input activation] (When Direct control function is selected)
• Operation of playback start by Pulse signal input activation
• Operations of playback start by Pulse signal input activation and Stop activation during playback.
Note
When set to Pulse signal input activation, playback is not repeated even if a closed state is kept at the end of
the program playback.
When set to Pulse signal input activation, set the closed duration of the make signal to the time duration not
longer than 1 second.