48
Binary control
Contact-activated input P002
Program playback
Playback control input
Contact-activated input P003
P002 playback
P002 playback start
P003 selection
P002 selection
Phrase recording
Contact-activated input 00002
Stop control input
Recording control input
Phrase 00002 recording
Stop activation
Recording start
Phrase 00002 selection
[(14) Playback operation by a Level signal input activation]
(Activation method)
Close the Playback control input terminal while the Contact-activated input terminal corresponding to the
program number to be played is being closed.
(Operation description)
Even if the P003 is selected by the Contact-activated input terminal during P002 program playback, P003 will
not be played regardless of the priority level, thereby keeping P002 playback as there is no Playback control
input signal for staring P003 playback.
[(15) Recording operation by a Pulse signal input activation]
(Activation method)
Close the Recording control input terminal while the Contact-activated input terminal corresponding to the
phrase number to be recorded is being closed.
(Operation description)
Audio source will be recorded to the Phrase No. 00002 when recording starts.
Recording stops when the Stop control input terminal is closed or the Start/Stop key is pressed.
Also, recording stops when the remaining recordable time reaches "0."
Note