71
18. MAINTENANCE FUNCTION
When any one of the switches of the DIP switch for Maintenance located inside the unit's front-mounted cover
is set to the ON position*
1
, the unit is placed in Maintenance mode, enabling the memory card backup and the
maintenance such as initialization of the unit settings.
The Maintenance indicator will flash when the unit is placed in Maintenance mode.
DIP switch for maintenance
Maintenance indicator
Notes
• When in Maintenance mode, operation by way of contact activation and using the EV-700 Setting software
cannot be made.*
2
When maintenance is complete, be sure to return all the switches of the DIP switch for
maintenance to the OFF position.
*
2
When only Switch 3 is set to the ON position, network setting using the EV-700 Setting software is available.
• Using the EV-700 Setting software, it is also possible to place the unit in Maintenance mode to perform
maintenance.
If any of the switches is set to the ON position, broadcast by way of contact control or using the EV-700
Setting software may not be activated. Be sure to return the switch to the OFF position when you finish work.
[Function of the DIP switch for maintenance]
The table below shows functions of each DIP switch for maintenance.
If a corresponding switch is set to the ON position, the unit is placed in Maintenance mode.
When you finish work in Maintenance mode, return the DIP switch to the OFF position.
If any one of the switches is set to the ON position, broadcast by way of contact control or using the EV-700
Setting software cannot be made.
1
2
3
4
5
6
7
8
Switch
Function
Indication on the Status display
Ref. page
1
Used to play all programs and also adjust whole
sound volume.
PG.VoL
2
Used to play, record, or delete Emergency playback
audio source.
EMEr
3
Used to upload or download the setting files between
the unit and memory card and also return the network
setting to the default values*
3
temporarily.
Download : SEtdL
Upload : SEtdL
4
Used to copy files on the memory card A to the
memory card B.
CFCPy
5
When set to the ON position along with Switch 8, the
firmware recorded on the memory card is updated.
Displays the current firmware version
number.
6
When set to the ON position along with Switch 8, the
unit setting is initialized.
Displays the target to initialize.
Settings other than the network: unit
Only network setting: nEt
All settings: ALL
7
When set to the ON position along with Switch 8,
Self-check will be executed.
During Self-check: tESt.
History storage memory error: Err51
8
Use this switch in conjunction with Switch 5 or 6.
−
*
3
Setting item
Default value
Setting item
Default value
Setting item Default value
IP address
192.168.14.1
Port number HTTP
8080
User name
EV700
Subnet mask
255.255.255.0
FTP control port
21
Password
guest
Default gateway
0.0.0.0
FTP data port
60020
Device name
EV-700
Device control
60007
System name
EV-700
*
1
When both Switches 7 and 8 are set to the ON position, the unit will not enter Maintenance mode.