7. PROGRAMMING DATA TABLE
INITIAL PROGRAMMING
Note. (Mark *)
The first station of each exchange becomes the Programming Station:
Exchange "A" . . . . . . . . . . . . . . . . . . . . . . . . . No. 200 (100)
Exchange "B" . . . . . . . . . . . . . . . . . . . . . . . . . No. 470 (400)
Exchange "C" . . . . . . . . . . . . . . . . . . . . . . . . . No. 740 (700)
Initial Programming of the Exchange
1.
Place program switch on front panel of the CP "ON"
Dial operation from station No. 200 (100). *
Dial tone will be heard (Station No. 200 (100) becomes a programming station)
Confirmation tone will be heard (Clears function group S)
Confirmation tone will be heard (Clears function group A)
Confirmation tone will be heard (Clears function group B)
Confirmation tone will be heard (Clears function group C)
Confirmation tone will be heard (Clears function group D)
Confirmation tone will be heard (Clears function group E)
Confirmation tone will be heard.
(Clears personal numbers, single digit dial numbers and remote numbers)
Program necessary functions.
(Refer to separate instructions for each function)
Place program switch on front panel of the CP in "OFF" position.
(Station No. 200 (100) becomes a normal station.) *
Clearance of Each Function at a Time
Confirmation tone
Confirmation tone
Establishment of Function on All Stations at a Time
— 40 —
All manuals and user guides at all-guides.com
all-guides.com